Safety precautions, A warning, Awarning – Kenmore POWER MISER 153.327164 User Manual

Page 2: A caution

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Safety Precautions

A WARNING

Improper installation, adjustment, alteration, service or
maintenance can cause DEATH, SERIOUS BODILY INJURY,
OR PROPERTY DAMAGE. Refer to this manual for assis­

tance or consult your local Sears Service Center for further

information.

AWARNING

At the time of manufacture this water heater was provided with
a combination temperature-pressures relief valve certified by a
nationally recognized testing laboratory that maintains periodic
inspection of production of listed equipment or materias, as

meeting the requirements for Relief Valves and Automatic Gas
Shutoff Devices for Hot Water Supply Systems, and the latest

edition of ANSI Z2I.22 and the code requirements of ASME. If

replaced, the valve must meet the requirements of local codes,
but not less than a combination temperature and pressure relief
valve certified as meeting the requirements for Relief Valves and
AutcHTiatic Gas Shutoff Devices for Hot Water Supply Systems,

ANSI Z2I.22 by a nationally recognized testing laboratory that

maintains periodic inspection of production of listed equipment
or materials.
The valve must be marked with a maximum set pressure not

to exceed the marked hydrostatic working pressure of the

water heater (ISO lbs./sq. in.) and a discharge capacity not

less than the water heater input rate as shown on the model
rating plate. (Electric heaters - watts divided by 1000 x 3415
equal BTU/Hr. rate.)
Your local jurisdictional authority, while mandating the use of a

temperature-pressure relief valve complying with ANSI Z2I.22
and ASME, may require a valve model different from the one fur­
nished with the water heater.
Compliance with such local requirements must be satisfied by

the installer or end user of the water heater with a locally pre­
scribed temperature-pressure relief valve installed in the desig­

nated opening in the water heater in place of the factory fur­

nished valve.

For safe operation of the water heater, the relief valve must not
be removed from it^ designated opening or plugged.
The temperature-pressure relief valve must be installed directly

into the fitting of the water heater designated for the relief valve.
Position the valve downward and pnmde tubing so that any dis­
charge will exit only within 6 inches above, or at any distance

below the structural floor. Be certain that no contact is made
with any live electrical part The discharge opening must not be
blocked or reduced in size under any circumstances. Excessive

length, over 30 feet, or use of more than four elbows can cause
restriction and reduce the discharge capacity of the valve.
No valve or other obstruction is to be placed between the relief

valve and the tank. Do not connect tubing directly to discharge
drain unless a 6" air gap is provided. To prevent bodily injury, haz­
ard to life, or property damage, the relief valve must be allowed

to discharge water in quantities should circumstances demand. If
the discharge pipe is not connected to a drain or other suitable
means,

the

water

flow

may

cause

property

damage.
The Discharge Pipe:

Must not be smaller in size than the outlet pipe size of

the valve, or have any reducing couplings or other
restrictions

Must not be plugged or blocked.

Must be of material listed for hot water distribution.

Must be installed so as to allow complete drainage of

both the temperature-pressure relief valve, and the
discharge pipe.

Must terminate at an adequate drain.

Must not have any valve between the relief vaJve and tank.

AWARNING

HAZARD

OF

ELECTRICAL

SHOCK!

Before

removing

any access panels or servicing the water heater, make
sure the electrical supply to the water heater is turned
“OFF”. Failure to do this could result in DEATH, SERI­
OUS BODILY INJURY, OR PROPERTY DAMAGE.

AWARNING

HOTTER

WATER

CAN

SCALD:

Water

heaters

are

intended to produce hot water. Water heated to a tem­
perature which will satisfy space heating, clothes washing,

dish washing, and other sanitizing needs can scald and

permanently injure you upon contact. Some people are
more likely to be permanently injured by hot water than

others. These include the elderly, children, the infirm, or

physically/mentally

handicapped.

If

anyone

using

hot

water in your home fits into one of these groups or if

there is a local code or state law requiring a certain tem­
perature water at the hot water tap, then you must take

special precautions. In addition to using the lowest possi­
ble temperature setting that satisfies your hot water

needs, a means such as a mixing valve, shall be used at
the hot water taps used by these people or at the water
heater. Mixing valves are available at plumbing supply or
hardware stores. Follow manufacturers instructions for
installation of the valves. Before changing the factory set­

ting

on

the

thermostat,

read

the

"Temperature

Regulation" section in this manual.

AWARNING

WATER

HEATERS

EQUIPPED

FOR

ONE

VOLTAGE

ONLY: This water heater is equipped for one type voltage
only. Check the rating plate near the bottom access panel
for the correct voltage. DO NOT use this water heater
with any voltage other than the one shown on the model
rating plate. Failure to use the correct voltage can cause

problems

which

cifT

resTjT£1n"DEArH,'SERlbUS

BODILY

INJURY. OR PROPlBXYJ?AMAGE-Jtyou have any ques­

tions or doubts consult your electric company.

AWARNING.-

INSULATING

JACKETS:

When

installing

an.external

water heater insOlSfTo'iTI'acket ón an~ electric water

heater:

.

----------------- ——

a. DO NOT cover the temperature-pressure relief valve.
b.

DO NOT put in8uUtion-wer-«he-»ccess-covers"or any

access areas.

c. DO NOT cover or remove operating instructions, and
safety related warning labels and materials affixed to the

water heater.

AWARNING

Do not use this appliance if any part of it has been under
water. An electrical short or malfunction could occur. The
water heater should be replaced.

A CAUTION

WATER

HEATERS

EVENTUALLY

LEAK:

Installation

of

the water heater must be accomplished in such a manner
that if the tank or any connections should leak, the flow of
water will not cause damage to the structure. When such
locations cannot be avoided, a suitable drain pan should
be installed under the water heater. Drain pans are avail­
able at your local Sears Store. Such a drain pan must be

piped to an adequate drain. Under no circumstances is

the manufacturer or Sears to be held liable for any water
damage in connection with this water heater.__________ ______

Advertising