SECTION 3

J jj:^.i.i J

jj

:^.^

■ ■

STEP BY STEP GUIDES TO INSTALL

E. PRESSURE TEST / CHECK FOR LEAKS

CAUTION:

To avoid water or air pressure damage to soft­

ener inner parts, and to flush pipe chips or
other residue from the water pipes, be sure to
do the following steps exactly as instructed.

Look at the picture in FIG. 15 showing your kind of
bypass valve(s).

Fully open two cold, soft water faucets nearby

the softener.

Place bypass valve(s) in "bypass" position. On
a single valve, slide the stem inward to bypass.
On a 3-valve system, close the inlet and outlet

valves and open the bypass valve.

FiG.14

HOUSE MAIN WATER

SHUTOFF VALVES

FiG.15

Bypass va!ve(s) should always remain in soft

water service position. Position in

bypass

only

if needed for softener repairs.

SINGLE BYPASS

o

Fully open the house main water pipe shutoff
valve (closed in step 1, page 3-1). Observe

steady water flow from both open faucets.

Place bypass valve(s) in ‘'service". EXACTLY as
follows: Keep soft water faucets open.

SINGLE BYPASS VALVE: SLOWLY, sHde pull
the valve stem outward toward service, pausing
several times to allow the softener to pressurize
slowly.

3-VALVE BYPASS: Fully close the bypass valve
and open the outlet valve. SLOWLY, open the

inlet valve, pausing several times to allow the

softener to pressurize slowly.

After about three minutes, open a hot water

faucet for about one minute, or until all air is
expelled, then close.

Close both cold water faucets.

Check your plumbing work for leaks and fix
right away if any are found. Be sure to observe
previous caution notes.

PULL STEM

OUTWARD

FOR

SERVICE

Push

Inward

For

Bypass

3 - VALVE BYPASS

FOR SERVICE

close bypass valve

open Inlet & outlet valves

FOR BYPASS

open bypass valve

close Inlet & outlet valves

3-7 Deluxe Valve