Operating mode descriptions, Temperature-pressure relief valve operation, Temperature-pressure relief valve operation -18 – Kenmore 153.32116 User Manual

Page 17

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Operating Mode Descriptions_______________

The operating modes can be changed by touching the desired

mode icon on the User Interface Module (see Figure 16.)
NOTE: All buttons on the User Interface are touch sensitive and

require only a light touch to actuate.

Operational Mode Buttons

d)

®

EFFICIENCY

VACATION

Hybrid Mode - This is the default, recommended

setting. Combining high energy efficiency with
reduced recovery time, this mode uses the heat
pump as the primary heating source. The heating
element will heat water if demand exceeds
a predetermined level so that the set point
temperature can be recovered more quickly.

Efficiency Mode - Is the most energy efficient
mode. This mode uses the heat pump to heat water
in the tank. The elements are not used unless the
ambient operating temperature is below 45°F or
above 109°F. If hot water demands are not met in
Efficiency Mode it may be necessary to switch to
Hybrid Mode.

Electric Mode - The water heater functions as a
conventional electric unit, relying totally on the

elements to heat the water in the tank. This mode

may be useful in winter to eliminate the output of
cold air from the unit.

Vacation Mode - The controller adjusts the water
temperature to approximately 60°F. This mode is

recommended when the water heater is not in use

for a long period of time. This mode effectively
turns the controller temperature setting down to a
temperature that prevents the water in the water

heater from freezing while still conserving energy.
NOTE: To activate the Vacation Mode touch the
vacation button. To deactivate Vacation Mode
touch the vacation button. IMPORTANT: The
anode protecting the tank requires power to the
unit to operate. Do not shut off power to the unit

for extended periods of time. If power must be
turned off for an extended period of time, drain the
tank completely.

Lock - Holding this button for more than 3 seconds

switches the lock mode on or off. When the User

Interface Module is locked a symbol and “Lock”

text will be visible on the display (see Figure 16).

°F/°C - The button switches the display to show
the set temperature in Fahrenheit or Celsius.

Heat Pump
Functioning
icon

Temperature'

Up (Increase
Button

Water
Temperature
Set Point

Water Heater

Efficiency Status

con

LCD Control
Panel Lock Icon

Temperature
Down (Decrease)
Button

Fahrenheit/Celsius

Temperature Display

Button

Power Button: On - Green

Standby - Red

LCD Display Panel
Lock Button

FIGURE 16.

Temperature-Pressure Relief Valve Operation

The temperature-pressure relief valve must be manually operated
at least once a year.

The temperature-pressure relief valve must be manually operated
at least once a year. Caution should be taken to ensure that
(1 ) no one is in front of or around the outlet of the temperature-
pressure relief valve discharge line, and (2) the water manually
discharged will not cause any property damage or bodily injury.
The water may be extremely hot.