CAUTION

Mineral Buildup or Sediment May Accumulate

This causes the water heater to become

much heavierthan normal.
If spilled, could cause staining.

This water heater, as well as all water heaters, will eventually
leak. Do not install without adequate drainage provisions so
water flow will not cause damage.

Mineral buildup or sediment may have accumulated in the old water
heater. This causes the water heater to be much heavier than normal
and this residue, if spilled out, could cause staining.

Facts to Consider About the Location________

You should carefully choose an indoor location for the new water
heater, because the placement is a very important consideration for
the safety of the occupants in the building and for the most economical
use of the appliance. This water heater is not intended for outdoor

instaiiation.

Whether replacing an old water heater or putting the water heater in a
new location, the following critical points must be observed.

Select a location near the center of the water piping system. The unit
must be installed indoors and in a vertical position on a level surface.
The flooring beneath the water heater must be able to support the

weight of the water heater when filled with water (See Table 1 ).

IMPORTANT: The water heater must be located in a space 750 cubic

feet or larger, and must have unrestricted airflow. As an example, a

room that has an 8 foot tall ceiling and is 10 feet long by 9-1/2 feet

wide would contain 760 cubic feet.

NOTE: For optimal efficiency and serviceability, the following
clearances should be maintained: 3 feet on the air inlet side, 5 feet,

on the air outlet side, 6 inches in the back, 4 inches above, and 2 feet

in the front.

The water heater should be located in an area not subject to freezing
temperatures. Water heaters located in unconditioned spaces (i.e.,
garages, basements, etc.) may require the water piping, condensate
piping, and drain piping to be insulated to shelter against freezing.
The drain and controls must be easily accessible for operation and
service.

The site location must be free from any corrosive elements in the
atmosphere such as sulfur, fluorine, and chlorine. These elements
are found in aerosol sprays, detergents, bleaches, cleaning solvents,
air fresheners, paint, and varnish removers, refrigerants, and many
other commercial and household products. In addition, excessive
dust and lint may affect the operation of the unit (See “Cleaning the

Filter” section).

The ambient air temperature must also be considered when installing
this unit. In Efficiency Mode the ambient air temperature must be
above 45°F and below 109°F. If the ambient air temperature falls
outside these upper and lower limits the electrical elements will
activate to meet the hot water demand and the heat pump does not
operate.

NOTE: Local codes and requirements in your area may require the
installation of your water heater be accomplished in a way that the
bottom element is elevated from the floor at least 18 inches. Ensure

that a platform capable of supporting the combined weight of the
water heater and water is used. Reference Table 1.

TABLE 1.

Capacity

Weight (filled with water)

60 Gallon

760 lbs

80 Gallon

967 lbs

CAUTION

Property Damage Hazard

All water heaters eventually leak

Do not install without adequate drainage.

WATER HEATERS EVENTUALLY LEAK: Installation of the water
heater must be accomplished in such a manner that if the tank
or any connections should leak, the flow of water will not cause
damage to the structure. When such locations cannot be avoided,
a suitable metal drain pan should be installed under the water
heater. Drain pans are available at your local Sears stores. Such
drain pans must be piped to an adequate drain.

Water heater life depends upon water quality, water pressure
and the environment in which the water heater is installed. Water
heaters are sometimes installed in locations where leakage may
result in property damage, even with the use of a metal drain pan
piped to a drain. However, unanticipated damage can be reduced
or prevented by a leak detector or water shut-off device used

in conjunction with a piped metal drain pan. These devices are
available from some plumbing supply wholesalers and retailers,
and detect and react to leakage in various ways:

• Sensors mounted in the metal drain pan thattriggeran alarm or turn

offtheincomingwatertothewaterheaterwhen leakage is detected.

• Sensors mounted in the metal drain pan that turn off the

water supply to the entire home when water is detected in the
drain pan.

• Water supply shut-off devices that activate based on the water

pressure differential between the cold water and hot water pipes
connected to the water heater.

CAUTION

Installations in Residential Garages

Water heater must be located in a

protective area.

INSTALLATION IN RESIDENTIAL GARAGES: The water heater
must be located and/or protected so it is not subject to physical

damage by a moving vehicle.

• The location selection must provide adequate clearances for

servicing and proper operation of the water heater.

Insulation Blankets_______________________

The use of an insulation blanket on this water heater is not
needed or recommended. The purpose of an insulation blanket

is to reduce the standby heat loss encountered with storage

tank heaters. Your water heater meets or exceeds the National
Appliance Energy Conservation Act standards with respect to

insulation and standby loss requirements, making an insulation

blanket unnecessary.