A warning, Checking for lp gas leaks, Warning – Kenmore 141.166801 User Manual

Page 15

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Connecting Natural Gas To Your Grill

For Natural Gas grills: The 12 foot Natural Gas

Hose has already been connected to Gas Mani­

fold as shown in Fig.Tc. Thread the 12 foot

Natural Gas Hose through the hole of Rear Panel
to outside. Also read the natural gas safety
instructions.(on page 4)

Figure 7c (Natural gas model only)

Install Pull-out Grease Tray

Place Heat Shield into Puil-out Grease Draining

Tray. The Heat Shield must be present and
centered for your safety. Slide the Pull-out
Grease Draining Tray into the Tracks on the Cart
Side Panels and push until it stops.
See Fig. 8.

•"¡sure 8

PULL-OUT GREASE
DRAINING TRAY

CART SIDE^

PANEL-RIGHT

Congratulations

Your Kenmore Elite gas grill is now ready

for use. Before the first use and at the

beginning of each season (and whenever the
LP gas tank has been changed):

1

. Read all safety, lighting and operating

instructions.

2. Check Gas Valve Orifices, Burner Tubes

and Burner Ports for any obstructions.

3.

Perform gas leak check according to

instructions found on page 15 of this
manual.

A

WARNING

A strong gas smell, or the hissing sound of
gas indicates a serious problem with your gas
grill or the LP gas tank. Failure to immedi­
ately follow the steps below could result in a
fire or explosion that could cause serious
bodily injury, death, or property damage.

Shut off gas supply to the gas grill.

Turn the Control Knobs to OFF position.

Put out any flame with a proper fire extin­
guisher.

Open Grill Lid.

Get away from the LP gas tank.

Do not try to fix the problem yourself.

. If odor continues or you have a fire you

cannot extinguish, call your fire departinent.
Do not call near the LP gas tank. Your tele­
phone is an electrical device and could create
a spark resulting in fire and/or explosion.

NOTE: The normal flow of gas through the
regulator and hose assembly can create a
humming noise. A low volume of noise is
normal and will not interfere with operation of

the grill. If humming noise is loud and exces­
sive you may need to purge air from the gas

line or reset the regulator excess gas flow

device. This purging procedure should be done
every time a new LP gas tank is connected
to your grill. For help with this procedure refer
to page 17, step 4, or call for assistance.

Customer Service Helpline:
Bam - 8pm CST, Monday through Friday

1-888-317-7642

Checking For LP Gas Leaks

Never test for leaks with a flame. Prior to first
use, at file beginning of each season, or every
time your LP gas tank is changed, you must
check for gas leaks. Follow these four steps:

1. Make a soap solution by mixing one part liquid

detergent and one part water.

2. Turn the grill Control Knobs to the full OFF

position, then turn the gas ON at source.

3. Apply the soap solution to all gas connections.

If bubbles appear in the solution the connec­

tions are not properly sealed. Check each

fitting and tighten or repair as necessary.

4. If you have a gas leak you cannot repair, turn

off gas at the source, disconnect fuel tine from
your grill and call 1-800-4-MY-HOME® or your
gas supplier for repair assistance.

15

Advertising
This manual is related to the following products: