THERMOSTAT

8.

Tighten terminals 2 and 3 to ensure proper electrical

connection.

5.

FIGURE 16.

Remove the screws from terminal 2 of the element, and

move the looped end of the wire aside.

FIGURE 17.

The buss bar is labeled 5500 W. Place the buss bar over

terminals 2 and 3 with the 5500 W visible. Install the extra

screw provided into terminal 3.

AWARNING

Fire and Explosion Hazard

Failure to tighten screws can

cause afire.

Failure to do this could result in

death, serious bodily injury, or

property damage.

Failure to tighten terminal screws can cause a fire which can

result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY

DAMAGE,

9.

Replace terminal cover on thermostat making sure that

the locking tabs on the terminal cover are in place.

AWARNING

Fire and Explosion Hazard

Thermostat

must

be

flush

against the tank.

Make sure terminal cover is in

place

and

the

insulation

replaced.

Failure to do this could result in

death, serious bodily injury, or

property damage.

Make sure the thermostat is flush against the tank, the terminal

cover is in place, and the insulation is replaced. Failure to do

so

can

result

in

DEATH,

SERIOUS

BODILY

INJURY,

OR

PROPERTY DAMAGE.

10.

Replace the insulation cap with handle so that it completely

covers the thermostat and element.

FIGURE 18.

7. The wire removed from terminal 2 has a looped end. It

must remain looped and now be placed (as shown) on

top of the buss bar, over the opening of terminal 2, and

secured using the remaining screw.

FIGURE 19.