11. Replace the access panel.

FIGURE 21.

12. Complete wiring to the water heater, or if completed, turn

"ON” electric power to the water heater after filling the tank

with water.

FIGURE 22.

CAUTION

Improper installation and use may result

in property damage.

Fill tank with water before operation.

Never use this water heater unless it is completely full of water.

To prevent damage to the tank and heating element, the tank

must be filled with water. Water must flow from the hot water

faucet before turning “ON” power.

Wiring

You must provide all wiring of the proper size outside of the

water heater. You must obey local codes and electric company

requirements when you install this wiring.

If you are not familiar with electric codes and practices, or if you

have any doubt, even the slightest doubt, in your ability to connect

the wiring to this water heater, obtain the service of a competent

electrician.

Contact your

Sears salesperson

to arrange for a

professional electrician.

WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY: This

water heater is equipped for one type voltage only. Check the

rating plate near the bottom access panel for the correct voltage.

DO NOT use this water heater with any voltage other than the

one shown on the model rating píate. Failure to use the correct

voltage

can

cause

problems

which

can

result

in

DEATH,

SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. If you

have any questions or doubts consult your electric company.

A

WARNING

Fire Hazard / Electric Shock Hazard

ê

Do not use this water heater with

any voltage otherthan shown on the

model rating plate.

Failure to use the correct voltage

shown

on

the

model

rating

plate

could result in death, serious bodily

injury, or property damage.

If wiring from your fuse box or circuit breaker box was aluminum

for your old water heater, replace it with copper wire. If you wish

to reuse the existing aluminum wire, have the connection at

the water heater made by a competent electrician. Contact your

Sears salesperson to arrange for a professional electrician.

1.

Provide a way to easily shut off the electric power when

working on the water heater. This could be with a circuit

breaker or fuse block in the entrance box or a separate

disconnect switch.

2.

Install and connect a circuit directly from the main fuse or

circuit breaker box. This circuit must be the right size and

have its own fuse or circuit breaker. Refer to the chart in the

"Product Specifications” section for the correct size wire and

fuse or circuit breaker.

3. If metal conduit is used for the grounding conductor:

a.

The grounding electrode conductor shall be of copper,

aluminum,

or

copperclad

aluminum.

The

material

shall be of one continuous length without a splice or

joint.

b.

Rigid

metal

conduit,

intermediate

metal

conduit,

or

electrical metallic tubing may be used for the grounding

means if conduit or tubing is terminated in fittings

approved for grounding.

c.

Flexible metal conduit or flexible metallic tubing shall

be

permitted

for

grounding

if

all

the

following

conditions are met:

The length in any ground return path does not exceed

6 feet.

The circuit conductors contained therein are protected

by overcurrent devices rated at 20 amperes or less.

The conduit or tubing is terminated in fittings approved

for grounding.

For

complete

grounding

details

and

all

allowable

exceptions,

refer to the current edition of the NEC - National Electrical Code

NFPA70.

4.

A standard 1/2" conduit opening has been made in the water

heater junction box for the conduit connection.