SYSTEM SPECIFICATION AND PERFORMANCE DATA
SHEET REFRIGERATOR WATER FILTER CARTRIDGE
MODEL 9005

Specifications

Service Flow Rate (maximum).........................................................0.75 GPM (2.83 Limin)
Rated Service Life Model 9005 (maximum).................................... 500 gallons/1892 liters
Maximum Operating Temperature...................................................100° F/38° C
Minimum Operating Temperature....................................................33° F/1° C

Minimum Pressure Requirement..................................................... 35 psi/138 kPa
Maximum Operating Pressure.........................................................120 psi/827 kPa

PERFORMANCE DATA

Substance

Influent Challenge

Concentration

Effluent

Average

Average %

Reduction

Maximum

Effluent

Min. Required

Reduction

Inlet

pH

Lead

0.15 mg/L+/-10%

0.001 mg/L

99.33%

0.001 mg/L

0.010 mg/L

6.5

Lead

0.15mg/L+/-10%

0.002 mg/L

98.66%

0.003 mg/L

0,010 mg/L

8.5

Cyst

Minimum 50,000/L

Icount/mL

99.99%

3 count/mL

> 99.95%

NA

Turbidity

11+/-1 NTU

0.12 NTU

98.98%

0.18 NTU

0.5 NTU

NA

Lindane

0.002 mg/L +/-10%

0.00005 mg/L

97.62%

0.00005 mg/L 0.00002 mg/L

NA

Atrazine

0.009 mg/L +/-10%

0.0002 mg/L

97.93%

0.0006 mg/L

0.003 mg/L

NA

Chlorine

2.0 mg/L+/-10%

0.09 mg/L

95.26%

0.17 mg/L

г75%

NA

Particulate**

at least 10,000

particles/mL

900 count/mL

99.68%

2400 count/mL

285%

NA

2,4-D

0.210 mg/L

+!-

10%

45,45 ug/L

84.42%

100 ug/L

0.0017 mg/L

NA

Asbestos

10'

to

10"

fibers/L; fibers greater

than

10

micrometers in length

0.16 MFL/mL

99.96%

0.16 MFL/mL

99%

NA

* Tested using a flow rate of 0,75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa)

under standard laboratory conditions, however, actual performance may vary. Health Claim
Performance tested and certified by NSF International

** Particle size range classification of test. Particles used were 0.5 -1 microns.

Stale of California

Depanment of Health Services

Water Treatment Device

Certificate Number

01

-

1486

Date Issued; September 21, 2001

Date RevUed: March 20,2002

Tbademark/Model Designation

WF50-WI500

WF50-NI300

WF50-KW15Ü0

WF50-KNB00

OWF50-WÍ500

■■

OWF50-NI300

^

Manufacturer; РеШлРиге tneocporaied

GENERAL USE
CONDITIONS

Read this Performance Data Sheet and

compare the capabilities of this
refrigerator with your actual water
treatment needs.

DO NOT use this product where water
is microbioiogicaiiy unsafe or of
unknown quaiity without adequate

disinfection installed before or after
filtration system. Systems certified
for cyst reduction may be used on
disinfected water that may contain

filterable cysts.

Use only with cold water supply.
Check for compliance with the state

and local laws and regulations.

The retractable water filtration system

uses a 9005 replacement cartridge (see
Sears contact information at the back of

your Use and Care Guide to order).
Timely replacement of filter cartridge is
essential for performance satisfaction
from this filtration system. Please refer

to the applicable section in this Use and

Care Guide for general operation,
maintenance requirements and

troubleshooting.

This system has been tested according
to ANSI/NSF 42 and 53 for reduction of

the substances listed below. The

concentration of the indicated
substances in water entering the system

was reduced to a concentration less than
or equal to the permissible limit for water
leaving the system, as specified in
ANSI/NSF 42 and 53.

WF5Û ,

WF5Ö ■

: 46 9005,.

46 9005 '

OWF5I

OWF5I

500 gal

300 gal

Thi: waler treatmeol devicets) list*donlhi.5,certiiicate have met the testing rtQuitEmenls pursuant to Section 116830 of the
Health and Safety Code for the foUowiag health related contaminants;

Microbiological Conlaminatasnnd 'ПлЫДИу

iBOgamc/Radiotneical Contaminante

Asbesss

Tested and certified by NSF International against ANSI/NSF Standards 42 and 53 in

models WF50-KNI300 and WF50-KWI500 for the reduction of:

Standard No. 42: Aesthetic Effects

Taste and Odor Reduction

Chlorine Reduction
Mechanical Filtration Unit

Particulate Reduction Class 1

Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane and 2, 4-D Reduction

Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction

tí)

PerrtaPure

1000 Apollo Road
Eagan, Minnesota U.S.A.
EPA EST #35917-MN-1

Rated Service Flow: 0.7S