If the grill fails to light properiy:

1. Turn gas off at source and turn the control knob

to OFF. Wait at least five minutes for gas to clear,
then retry.

2. Check gas supply and connections.

3. Repeat lighting procedure. If your grill still fails

to operate properly, turn the gas off at source,
turn the control knobs to OFF, then check the

following:

• Misalignment of burner tubes over orifices

Correction: Reposition burner tubes over orifices.

• Obstruction in gas line

Correction: Remove fuel tine from grill. Do not
smoke! Open gas supply for one second to clear
any obstruction from fuel line. Close off gas
supply at source and reconnect fuel line to grill.

• Plugged orifice

Correction: Remove burners from grill by

pulling cotter pin (beneath burner) using a

screwdriver or pliers. Carefully lift each burner

up and away from gas valve orifice. Remove the
orifice from gas valve and gently clear any
obstruction with a fine wire. Then reinstall all
orifices, burners, cotter pins and cooking

components.

If an obstruction is suspected in gas valves or

gas valve bracket, please call for repair service

at 1-800-4-MY-HOME.

• Misalignment of ignitor on burner

Correction: Check for proper position of the
electrode tip as shown in Figure 13. The gap

between the Spark Electrode Tip and Spark
Receiver should be approximately 3/16”. Adjust
if necessary. With the gas supply closed and all

control knobs set to OFF press the electric

ignitor cap and check for the presence of a
spark at the electrode.

• Disconnected Ignition Wires

Correction: Inspect the Ignitor junction box
found behind the Control Panel, Connect loose

Ignitor wires to junction box and try to light the

grill.

• Weak AA battery

Correction: Unscrew the Ignitor Cap and
replace the battery.

4. If the grill still does not light you may need to

purge air from the gas line or reset the
regulator excess gas flow device. Note: This
procedure should be done every time a new

LP gas tank is connected to your grill.

To purge air from your gas line and/or

reset the regulator excess gas flow device;

• Turn the control knobs to the OFF position.

• Turn off the gas at the tank valve.
• Disconnect regulator from LP gas tank.
• Let unit stand for 5 minutes.

• Reconnect regulator to the LP gas tank.
• Turn the tank valve on slowly until 1/4 to

1/2 open.

• Open the Grill Lid or Side Burner Lid.
• Set control knobs to OFF and open the LP

gas tank valve.

• To light grill push and turn the LEFT

control knob to HIGH. To light the Side

Burner turn its control knob to HIGH.

5. If all checks or corrections have been made and

you still have questions about operating your gas

grill, call the Manufacturer’s Customer Sen/ice
Helpline Sam - 8pm CST, Monday through Friday
at

1-888-317-7642

A

warning

Should a "FLASH-BACK" fire occur in/or
around the burner tubes, follow the in­
structions below. Failure to comply with

these instructions could result in a fire or

explosion that could cause serious bodily

injury, death, or property damage.

• Shut off gas supply to the gas grill.
• Turn the control knobs to OFF position.
• Put out any flame with a fire extin

guisher.

• Open grill lid.
• Once the grill has cooled down, clean

the burner tubes and burners according

to the cleaning instructions found on
page 19 in this manual.