Housekeeping, Anode rod inspection, Temperature-pressure relief valve operation – Kenmore 153.339432 User Manual

Page 27: Draining and flushing, Draining and flushing -28, Caution, Âdanger, Adanger

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Housekeeping

Vacuum around base of water heater for dust, dirt, and lint on

a regular basis.

ÂDANGER

Fire and Explosion Harzard

Do not obstruct combustion air

openings at the bottom of the
water heater.

Do not use or store flammable

vapor products such as gasoline,
solvents or adhesives in the
same room or area near water
heater or other appliance.

At least annually, check the

base-ring filter and flame arrester

for any dust, lint, or debris that

may have accumulated. Clean
as necessary.

Can cause serious injury or death.

AT LEAST ANNUALLY, A VISUAL INSPECTION SHOULD BE

MADE OF THE BASE-RING FILTER AND FLAME ARRESTER.
CLEAN IF LINT ACCUMULATIONS ARE NOTICED.

INSTALLED IN SUITABLE AREA: To ensure sufficient ventilation

and combustion air supply, proper clearances from the water

heater

must

be

maintained.

See

“Installation

Instructions.”

Combustible materials such as clothing, cleaning materials, or

flammable liquids, etc. must not be placed against or adjacent

to the water heater because they could catch on fire.

Anode Rod Inspection

CAUTION

Property Damage Hazard

' Avoid water heater damage.

' Inspection and replacement of anode rod required.

The anode rod is used to protect the tank from corrosion.

Most hot water tanks are equipped with an anode rod. The

submerged rod deteriorates to protect the tank. Instead of

corroding the tank, water ions attack and eat away the anode

rod. This does not affect the water’s taste or color. The rod

must be maintained to keep the tank in operating condition.

Exposed

Pitted

Exposed

Anode

deterioration

depends

on

water

conductivity,

not

necessarily water condition. A corroded or pitted anode rod
indicates high water conductivity and should be checked and/
or replaced more often than an anode rod that appears to be
intact. Replacement of a depleted anode rod can extend the
life of your water heater. Inspection should be conducted by
calling the Sears Service Center for an authorized contractor.

At a minimum, the anode(s) should be checked annually after
the warranty period.

Temperature-Pressure Relief Valve Operation

The

temperature-pressure

relief

operated at least once a year.

valve must be manually

When checking the temperature-pressure relief valve operation,

make sure that (1 ) no one is in front of or around the outlet of

the temperature-pressure relief valve discharge line, and (2)
that the water discharge will not cause any property damage, as
the water may be extremely hot. See Figure 30.

TEMPERATURE-PRESSURE

RELIEF VALVE

DISCHARGE PIPE

FIGURE 30.

If after manually operating the valve, it fails to completely reset

and continues to release water, immediately close the manual
gas shut-off valve and the cold water inlet valve and call the
Sears Service Center.

If

the

temperature-pressure

relief

valve

on

the

appliance

weeps or discharges periodically, this may be due to thermal
expansion. You may have a check valve installed in the
water line or a water meter with a check valve. Consult the

Sears Service Center for further information. Do not plug the
temperature-pressure relief valve.

Draining and Flushing

ADANGER

• Hotwaterdischarge burn hazard.

• Keep clear of relief valve discharge

unit.

• Temperature limiting valves are

available.

• Read instruction manual for safe

temperature setting.

It is recommended that the tank be drained and flushed

every 6 months to remove sediment which may build up during

27