Replacing the Manifold/Burner Assembly

AWARNING

Explosion Hazard

Tighten both manifold door screws securely.

Remove any fiberglass between gasket

and combustion chamber.

Replace viewport if glass is missing or

damaged.

Replace two piece wire connector if missing or

removed.

Replace door gasket if damaged.

Failure to follow these instructions can result

in death, explosion, or fire.

1.

Check the door gasket for damage or imbedded debris

prior to installation.

2.

Inspect the view port for damage and replace as required.

3.

Insert

the

manifold/burner

assembly

into

the

burner

compartment, making sure that the tip of the manifold tube
engages in the slot of the bracket inside the combustion

chamber (Figures 39 & 40).

4.

Inspect the door gasket and make sure there is no

fiberglass

insulation

between

the

gasket

and

the

combustion chamber.

5.

Replace the two screws, which secure the manifold/

burner assembly door to the combustion chamber and

tighten securely. Once the manifold/burner assembly door

is tightened, visually inspect the door gasket between

the manifold/burner assembly door and the combustion

chamber for spaces or gaps that would prevent a seal.

IMPORTANT: Do not operate the water heater if the door

gasket does not create a seal between the manifold door

and the combustion chamber.

6.

During the following procedure, do not cross-thread or

apply any thread sealant to any of the fittings listed below.

First, reconnect the manifold tubing to the gas control valve/

thermostat. NOTE: L.P. gas systems use reverse (left-hand)

threads on the manifold tube.

NOTE: If a ferrule nut needs to be installed for the pilot

tube, locate the one provided with your parts kit. Install it in

the gas control valve/thermostat at the pilot location, hand

tight only.

Next, insert the pilot tube into the ferrule nut until it bottoms

out. NOTE: Hold the tube in this position. Tighten the ferrule

nut with a wrench until the crimp connection seals to the

pilot tube. Continue to tighten until the nut is tight in the gas

control valve/thermostat. Finally, start the thermocouple nut

and turn it all the way in by hand. An additional quarter turn

with a 3/8” open-end wrench will then be sufficient to seat

the lockwasher. When you are finished, connect the two

wire leads that go to the thermal switch.

7.

Reconnect the igniter wire.

8.

Turn gas supply on and refer to the Lighting Instructions.

9.

With the burner lit, check the gas control valve/thermostat

supply line, two piece wire connector, manifold tube,

and pilot tube connections for leaks. Check for leaks by

brushing

on

an

approved

noncorrosive

leak

detection

solution. Bubbles forming indicate a leak. Correct any leak
found. IMPORTANT: All leaks must be fixed immediately.

10. Replace the outer door.

FLAME ARRESTOR BRACKET

MANIFOLD TUBE

FIGURE 40.

Piezoelectric Igniter System

The piezoelectric igniter system consists of the igniter button,
electrode, and wire. The pilot is ignited by an electric spark

generated when the igniter button is pressed. The spark gap

of 0.125 inch is set when the electrode is installed at the factory.
(Figure 41). Use only factory authorized piezoelectric igniter

parts for replacement.

THERMOCOUPLE

* NOTE: SPARK GAP DISTANCE MEASURED FROM ELECTRODE TIP TO PILOT.

FIGURE 41.