prevent possible piping stress and damage during the transfer of refrigerant from vessel to

vessel during the leak test process, or any time refrigerant is transferred. Adjust the springs

when the refrigerant is in operating condition, and when the water circuits are full.

Refrigerant Tracer

Carrier recommends the use of an environmentally acceptable refrigerant tracer for leak

testing with an electronic detector or halide torch.

Ultrasonic leak detectors also can be used if the machine is under pressure.

Leak Test Machine

Due to regulations regarding refrigerant emissions and the difficulties associated with

separating contaminants from refrigerant, Carrier recommends the following leak test

procedures. See

Figure 28

for an outline of the leak test procedures. Refer to

Table 5A

and

Table 5B

for refrigerant pressure/temperature values and to

Pumpout and Refrigerant Transfer

Procedures

section.

Do not use air or oxygen as a means of pressurizing the machine. Some mixtures
of HFC-134a and air can undergo combustion.