Note: Drive shaft end-float at final drive position must not allow coupling hub faces to contact,

or the coupling shroud to bind.

Preliminary Alignment

To get within dial indicator range, roughly align the equipment as shown in

Figure 37

and as

described below.

Place a straight edge across the OD of one coupling to the OD of the other. Measure the gap

between the straight edge and the OD of the second coupling with a feeler gage. Then, by

adding or removing shims at each corner, raise or lower the equipment by the measured

amount.

In a similar manner, measure the shaft offset from side to side and jack the equipment over

as required to correct.