Troubleshooting if the grill fails to light, Follow the steps below to reset the flow – Kenmore LIQUID PROPANE GAS (LPG) GRILL 119.1623 User Manual

Page 27

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

USE AND CARE INSTRUCTIONS

Troubleshooting

If the grill fails to light;

1. Turn gas off at source and turn control knobs

to "OFF". Wait at least 5 minutes for gas to
clear, and then retry

2. If your grill still fails to light, check the gas

supply and connections. Ensure gas supply
is turned on (turn counterclockwise), there
is gas in the tank, and the regulator is
properly seated in the tank valve.

3. Repeat lighting procedure. If your grill still

fails to light, turn the gas off at the source,

turn the controi knobs to "OFF", and check
the following:

Obstruction in Gas Line

Correction;

Detach regulator hose assembly.

Do not smoke! Open all control knobs at the
same time to "High". Close all burner control
knobs to "OFF" and reattach the regulator hose
assembly to the grill.

Plugged Orifice or Burner Tube Obstruction

Correction;

Remove burners from grill and

clean following the burner cieaning instructions
later in this manual. Observe valve orifice to be
sure there is no obstruction visibie.

If an obstruction is suspected in Gas Vaive or
Manifold, call the Customer Support Center.

Misalignment of Igniter and Burner

Correction;

Check for proper position of the

electrode tip. The gap between the electrode tip
and burner should be approximately 3/15 of an
inch. Adjust if necessary. With the gas supply off
and all control knobs set to "OFF" press the
electric igniter button and check for the
presence of a spark at the electrode.

D Disconnected Electric Wires

Correction;

Inspect the electric igniter (see

Parts List) found behind the controi panel.
Connect loose electric wires to ignition
assembly.

Weak AA Battery

Correction;

Unscrew the igniter cap and replace

the battery.

ZK

A

Do not dispose of batteries in fire! Batteries may
explode or leak.

n If the grill still does not light you may need to

reset the flow limiting valve in your LP tank.

Note;

This procedure should be done every

time a new LP gas tank is connected to your
grill.

Follow the steps below to reset the flow
limiting device.

Turn LP gas tank valve "OFF".

Disconnect the regulator assembly from LP
Gas tank.

Open all burner control knobs to

"HI/LIGHT" at the same time.

Close all burner control knobs to "OFF"

n Let the LP Gas tank stand for at least 10

minutes.

D Reconnect the regulator assembly to the LP

Gas tank.

n Slowly turn on the LP Gas tank valve.

Follow the burner lighting procedures to
light the burner farthest away from the gas
source.

A.

Should a FLASHBACK fire occur in or around

the burner tubes, follow the instructions

beiow. Failure to comply with these
instructions could result in a fire or explosion

that could cause serious bodily injury, death,

or property damage.

Shut off gas suppiy (turn the LP tank
vaive clockwise) to the gas grill.

Turn the control knobs to the "OFF"

position.

Open the grill lid.

Put out any flame with a Class B Fire
extinguisher

Once the grill has cooled down, clean the
burner tubes and burners according to
the cleaning instructions in this
Operator's Manual.

Customer Support Center

Call 8:30 AM to 5:00 PM CST

1-800-933-0527

Monday through Friday.

27

Advertising