Calibration Menu

CALIBRATION MENU

Touch Perform Calibration. The message “Touch Upper Left” appears centered on
the panel with a cross hair in the upper left corner. Touch the center of the cross hair
in the corner of the screen to initiate calibration. Another message, “Touch Upper
Right”, appears with a cross hair in the correct corner. Touch the center of the cross
hair in the corner of the screen. A final message, “Touch Lower Right”, appears with
a cross hair in the correct corner. Touch the center of the cross hair in the corner of
the screen to conclude calibration and return to the CALIBRATION MENU.

NOTE: When touching the screen during calibration be as accurate as possible. Use
the tip of a capped pen or the eraser end of a pencil. To cancel calibration and return
to the CALIBRATION MENU without saving calibration data, create a calibration
error by touching the screen in the same spot three times.