TO REMOVE COMBUSTION TUBE ASSEMBLY FOR

INSPECTION, CLEANING AND REPLACEMENT

SERVICE MUST BE PERFORMED BY A
QUALIFIED SERVICE AGENCY.

A.)

Turn thermostat to “OFF” or lowest
setting. Allow heater to cool.

B.)

Turn off electric power to heater.

C.)

Remove front panel.

D.)

Turn gas supply valve to “OFF”.

E.)

Disconnect gas supply line from gas valve.

F.)

From outside, remove six (6) screws
securing back of outer cabinet to air in
take and exhaust flanges. (See Figure 5).

G.)

From inside, gently slide combustion tube
assembly forward and out of outer
cabinet. (See Figure 6).

H.)

Disconnect air pressure switch tubing
from draft inducer. (See Figure 18-B).

I.)

Remove draft inducer. (See Figure 18-B).

J.)

Disconnect ignition cable and pressure
switch tubing from top of burner box.
(See Figure 16).

K.)

Remove screws securing collection box
flange and burner box flange to inner
casing top, bottom, and back.
(See Figure 19).

L.)

Pull combustion tube assembly forward
and out. (See Figure 20).

M.)

You can now inspect, clean or replace
tubular heat exchanger as needed.
NOTE: If combustion tube assembly is
being replaced, you must keep and use
collection box and burner box from
assembly being replaced.

N.)

Carefully check integrity of all gaskets
(replace as needed), then reinstall combustion
tube assembly by reversing Steps L - A.
Follow lighting instructions to put heater in
operation.

FIGURE 16

IGNITOR

IGNITOR
CABLE

PRESSURE
S W I T C H
TUBING

BURNER
BOX

FIGURE 19

FIGURE 18-B (For WOW403 / WOW404)

Circulating
Blower #2

Circuit
Board

Transformer

Junction
Box

Air Intake

Pressure
Switch

Circulating
Blower #1

Liner

Draft
Inducer

FIGURE 20