Error Messages

Message

Cause(s)

Action(s)

Lamp Startup Fail

The lamp has not started after being
struck.

• Check lamp

• Check lamp socket and wiring
• Check ballast and igniter

Temperature Sense Fail

There is no communication with
temperature sensor.

• Check sensor wiring

• Check sensor integrity
• Check control board

Lamp Hot Protection

Fixture temperature is higher than 105º C;
lamp was switched to low power for safety.

• Check fans
• Check fan wiring

• Clean vents

Lamp Hot Power Off

Fixture temperature is 110º C or higher;
lamp was switched to off for safety.

• Check fans
• Check fan wiring

• Clean vents

Maintenance Fixture

Fixture Maintenance timer expired.

• Proceed with maintenance and reset timer

Lamp On Over 700 Hour Lamp change is overdue.

• Change lamp

Memory Initial Fail

Memory chip error found.

• Change main board

Fan 1 Error
Fan 2 Error
Fan 3 Error
Fan 4 Error
Fan 5 Error
Fan 6 Error

The indicated fan is not working.

• Check fan
• Check fan wiring

CPU-B Error
CPU-C Error
CPU-D Error
CPU-E Error
CPU F Error
CPU G Error
CPU H Error

There is no communication with the
indicated auxiliary CPU.

• Check sensors’ wiring and position
• Check stepper motor, belt, and driver board
• Check control boards

Pan Home Sensor Error
Pan Encode Error
Tilt Home Sensor Error
Tilt Encode Error

The moving head failed going to home
position after power up or fixture reset.

• Check moving head’s free movement
• Check sensors’ wiring and position

• Check stepper motor, belt ,and driver board
• Check the corresponding control board
• Check main control board

Color 1 Reset Fail
Cyan Reset Fail
Magenta Reset Fail
Yellow Reset Fail
3200 K Filter Reset Fail
Gobo 1 Reset Fail
R-Gobo 1 Reset Fail
Gobo 2 Reset Fail
R-Gobo Reset Fail
Iris Reset Fail
Effect Reset Fail
R-Effect Reset Fail
Frost Reset Fail
Focus Reset Fail
Zoom Reset Fail

The indicated moving part failed going to
home position after power up or fixture
reset.

• Check part’s free movement and integrity
• Check sensors’ wiring and position
• Check stepper motor, belt, and driver board

• Check the corresponding control board