Troubleshooting guide, Technical information – Chauvet 1200E User Manual

Page 33

Advertising
background image

Technical Information


Legend™ 1200E Spot User Manual Rev. 03c

-29-

Troubleshooting Guide

Symptom

Cause(s)

Action(s)

Fixture does not power up

• No power on outlet

• Repair outlet problem or use another outlet

• Blown fuse

• Replace blown fuse with same type and rating

fuse

• Bad power cord/plug

• Repair or replace power cord/plug

• Bad power switch

• Replace power switch

• Bad power supply

• Replace power supply

• Bad main controller

• Replace main controller

Fixture powers up but
lamp does not ignite

• State/Power On parameter set to NO

• Change parameter to YES

• Lamp temperature problems

• Check error messages and follow instructions

• Lamp problems

• Check error messages and follow instructions

Lamp ignited but has low
intensity/color
temperature

• Dimmer not at full output

• Adjust dimmer value

• Lamp still cold

• Wait for lamp to come up with full output

temperature

• CTC or CMY filter interfering

• Set color wheel or filter to home position

• Defective or old lamp

• Replace lamp

• Misaligned lamp

• Realign lamp

• Defective lamp wires or socket

• Repair/change wiring or socket

• Defective ballast

• Replace ballast

Lamp flickers or turns off
by itself

• Defective or old lamp

• Replace lamp

• Temperature problems

• Check error messages and follow instructions

• Defective lamp wires or socket

• Repair/change wiring or socket

• Defective ballast

• Replace ballast

Circuit breaker/fuse keeps
tripping/blowing

• Excessive circuit load

• Check total load placed on the electrical circuit

• Short circuit along the power wires

• Check for a short in the electrical wiring

Fixture does not respond
to DMX when nearby
fixtures on the same
universe do

• Wrong DMX addressing

• Check DMX mode and starting DMX address

• Damaged DMX cables

• Check DMX cables

• Wrong polarity on the controller

• Check polarity switch settings on the controller

• Loose DMX cables

• Check cable connections

• Faulty DMX interface

• Replace the Main board

• Faulty Display/Main board

• Replace the Main board

DMX signal problems

• Non DMX cables

• Use only DMX compatible cables

• Bouncing signals

• Install terminator as suggested

• Long cable / low level signal

• Install an optically coupled DMX splitter right

after the fixture with the strong signal

• Too many fixtures

• Install an optically coupled DMX splitter after

unit #32 or before

• Interference from AC wires

• Keep DMX cables separated from power

cables or fluorescent/black lights

If you still experience technical problems after trying the above solutions, contact
CHAUVET® Technical Support.


Advertising