background image

ASCII Message Storage in Register & Program Memory

T1/T1S can store ASCI) messages in either program memory, register memory, or both. There are over

1,000 data registers on the standard T1 and over 4,000 data registers on the TIS that can be used tor

ASCII message storage. This makes T1 s ideal for use with the low-cost operator interface stations that

require massages to be stored in the PLC.

High-Speed Counter Input

The T1/T1S has twro high-speed counter inputs {DC input types only). These 5 kHz counters can be

used independently {of each other and of CPU scan) for discrete parts count in applications requiring

high-speed compare, reset, and strobe. The counters can also be used together as a quadrature

counter.

Pulse Encoder

Phase A
Phase

B

5 kHz max, for each phase

Both risirrg and failing edge of each phase are counted.

20 k counts per second max.

tjT «W|

Analog Register Adjustment

Each T1/T1S has two terminals {which can be adjusted with a screwdriver) that vary the value In two

separate registers. These registers can be used as presete for timers and counters, maximum,

rninimum, or equal values for comparisons, add or subtract adjustments, etc.

Pulse^PWM Output

An output from theT1/T1S can generatea variable frequency output {5 kHz max.). The output can also

be driven so that h switches ON and OFF at varying duty cycles. This output can ba used to drive a

stepper motor or to simulate an analog output (DC input types only).

Stepper Motor Driver

CW Pulse
CCW Pulse

_nnn_

Output pulse rate; 50 Hz to 5 kHz

Stepper Motor

Password Protection

The T1/T1S can ba programmed with no password, or with one of three selectable protection levels.

This is a serious password utility. There is no way for anyone to recover, modify or view a fully

protected program.

Advertising
This manual is related to the following products:

T1