V. Operation

Be sure to check all safety and environmental conditions.
A wire rope should be discarded and not to be used again if rope shows sign of excessive
wear too many broken wires, corrosion or other defects.
The operator of winch must remain with the winch at all times whist the unit is being operated.
The type of duty is intermittent-periodic duty S3 and the load time never exceeds 2 minutes.
If a winch fails in pulling a load at a normal condition, stop the operation within 30 seconds,
otherwise you will damage the motor.
Ensure that only the rated voltage is applied to the winch (ie. 12VDC or 24VDC).
Do not wrap the wire rope around load and hook it to itself. Always use a strap to insure that
the wire rope does not fray or kink.
Keep hands and clothes away from the drum area, wire rope and roller fairlead.
Never unplug the remote control when winching a load.
Determine that the winch is operating correctly before use.
To avoid insufficient power in pulling a load, the vehicle should be running and in neutral.
The handbrake should be also on.
If noise or vibration occur while running, stop the winch immediately and send it for repaired.
Don’t use it again before trouble shooting completely.
If the winch is not to be used for a long time, we recommend disconnecting the battery lead
from winch.

1). To determine “Cable - Out”, depress ↑ button (fig. 10)
2). To determine “Cable - In” depress ↓ button (fig.11)
3). To stop winching, release the button

8

Precaution

Cable-in/ Cable-out Operation

Advertising