Trouble shootings – COMEUP Chain Hoist (Ver:02) User Manual

Page 15

Advertising
background image

13

Before performing any troubleshooting on the chain hoist, de-energize the supply of electricity
as hazardous voltages are present in the hoist and in connections between components.

Trouble Shootings

Symptom

Possible cause

Remedy

Hoist will not

operate

Loss of power or wrong voltage/frequency

Check power supply against the rating on the

name plate

Power cutoff switch lights red

Reduce load to within rated capacity of hoist

and reset by manual

Motor overheated

Take a rest and perform the hoist according to

its duty cycle percentage rated at 25%ED

Motor burned out

Replace motor

Brake does not release

Check or replace brake assembly

Improper installation or wearing of carbon

brush

Check or replace carbon brush

Escape or open circuit of carbon brush lead

Check or replace carbon brush lead

Can lift, but fail to

lower

Down circuit open

Check down limit switch for malfunction

Malfunction of the Down contact of the pendant

switch

Replace pendant switch

Can lower, but fail

to lift

Down circuit open

Check down limit switch for malfunction

Hoist overloaded

Reduce load to within rated capacity of hoist

Considerable voltage drop

Applied voltage shall fall into ±10% of rated

voltage on the name plate.

Fault friction clutch

If abnormal operation or slippage occurs do not

attempt to disassemble or adjust the friction

clutch. Replace the malfunctioning friction

clutch with a new or factory adjusted part.

Malfunction of the Up contact of the pendant

switch

Replace pendant switch

Short circuit

Melted B contact of pendant switch

Replace pendant switch

Burnt diode

Replace diode and pay attention to its poles

Burnt D type resistor

Replace resistor

Having too much carbon powder on carbon

brush holder

Disassembly the motor and clean carbon

powder

Burnt motor

Replace motor

Fail to lift the load

rated

Hoist overloaded

Reduce load

Considerable voltage drop

Applied voltage shall fall into ±10% of rated

voltage on the name plate

Incorrect carbon brush specification or too

short

Replace carbon brush

Burnt, deformation of carbon brush holder

Replace carbon brush holder

Load drifts

excessively when

hoist is stopped

The gap of ratchet brake is too large

Adjust the ratchet brake

Malfunction of pressed spring of ratchet brake Replace the pressed spring

Oil leakage

Improper installation of cap screw

Proper installation of cap screw

Damaged or deformed oil packing

Replace oil packing

Fail to install oil packing

Install oil packing

Advertising