Warning, 6determination of the fem classification, Rated percentage duty cycle (%ed) – COMEUP Chain Hoist (Ver:02) User Manual

Page 8

Advertising
background image

6

Determination of the FEM Classification

The service life of the product is significantly dependent on the frequency at which it is operated.
To ensure long service life, operate the winch within its rated percentage duty cycle (%ED).
The rated percentage duty cycle (%ED) is expressed by the duty factor (%ED) obtained at the
rated voltage and the frequency at 63% of the rated load.
( lifting time + lowering time )
Percentage duty cycle (%ED) ------------------------------------------------------------------ X 100 (%)
( Duty Factor ) ( lifting time + idle time + lowering time + idle time )
The maximum startup frequency represents the frequency of startup operations per hours,
including inching operations. The rated speed, which indicates the average speed of winding
up or down at a rated load. A cycle is limited at 10 minutes at most.

Rated Percentage Duty Cycle (%ED)

Load

Spectrum

State of Loading

Cubic

Mean

Value

Average Daily

Operating Time

in hours

Calculated Total

Operating Time

in hours

Light

Occasional full load;

Usually light load;

Small fixed load

k 0.5

2

3,200

Medium

Occasional full load;

Usually light load;

Average fixed load

0.5 k

0.63

1

1,600

Heavy

Repetitive full load;

Usually average load;

Heavy fixed load

0.63 k

0.8

0.5

800

Very Heavy

Usually almost full

load; Very heavy

fixed load

0.8 k 1

0.25

400

WARNING

Do not exceed the rated intermittent period.

100%

40%

10%

10

40

50

100%

17

50

17

17

73%

47%

100%

40%

50

50

100%

90

10

80%

20%

Operating time%

Load%

Operating time%

Operating time%

Operating time%

Load%

Load%

Load%