Hardware Installation

RocketLinx ES7110 and ES7110-VB User Guide: 2000552 Rev. C - 7

Hardware Installation

You can use the following subsections to install the RocketLinx ES7110:

Setting the DIP Switch

Connecting the Power

on Page 8

Wiring the Relay Output and Ground

on Page 9

Mounting the RocketLinx ES7110

on Page 10

Connecting the Ethernet Ports

on Page 10

Front Panel and LEDs

on Page 12

Setting the DIP Switch

The ES7110 has a 10-pin DIP switch located on the bottom of the switch to configure the Port Link Alarm for the Ethernet
ports. The following table shows the DIP switch number mapping to the corresponding PoE and Gigabit ports as follows.

Port G2

Port G1

Port 1

Port 2

Port 3

Port 4

Port 5

Port 6

Port 7

Port 8

DIP 1

DIP 2

DIP 3

DIP 4

DIP 5

DIP 6

DIP 7

DIP 8

DIP 9

DIP 10

DIP Switch Number

Status

Description

1-2

On

Enables the Gigabit port link failure alarm for this port.

Off

(Default)

Disables the Gigabit port link failure alarm for this port.

3-10

On

Enables the PoE port link failure alarm for the
corresponding port.

Off

(Default)

Disables the PoE port link failure alarm for the
corresponding port.

Advertising
This manual is related to the following products: