Caution, Application considerations – Carrier INFINITY 2020 User Manual

Page 2

Advertising
background image

2

PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal injury.
Ozone in concentrations above 0.05 PPM may be

hazardous to health.
Des concentrations d’ozone superieures a 0.05 PPM

peuvent etre nocives pour la sante.

CAUTION

!

APPLICATION CONSIDERATIONS

The Infinityt Air Purifier is designed for use in the return air

duct of a forced air heating, cooling, and ventilation system.

Models

GAPABXCC1620,

GAPABXCC2020

and

GAPABXCC2420 are specifically designed for use in systems

with a fan coil.
Air Conditioning
The Infinityt Air Purifier should be installed in a system so that

all the return air is circulated through the air purifier. It should be

located upstream of the fan coil This will help keep the fan coil

clean and prevent condensation from forming within the

Infinityt Air Purifier.
Humidifiers
An evaporative humidifier can be mounted upstream of the

Infinityt Air Purifier. It is best to install atomizing humidifiers

downstream of the air purifier because hard water salt deposits

and water droplets may damage the air purifier. If an atomizing

humidifier must be mounted upstream of the Infinityt Air

Purifier, it should be mounted as far upstream as possible (at least

6 ft. recommended), and a standard disposable furnace filter

should be mounted between the humidifier and the air purifier to

trap hard water salt deposits and water droplets.

Transitions
If the return air duct or fan coil openings do not fit the Infinityt

Air Purifier cabinet

openings,

gradual

transitions are

recommended to reduce air turbulence and maximize efficiency.

No more than 20 degrees (about 4 in. per running ft.) of

expansion should be used on each side of the transition fitting.
Turning Vanes
If the Infinityt Air Purifier is installed adjacent to a 90 degree

duct elbow, turning vanes should be added inside duct to improve

air distribution across the face of the air purifier.
Electrical Power / Air Flow Sensor
The Infinityt Air Purifier should only be powered when airflow

is present. This model is designed for use with a fan coil and is

equipped with an air flow sensor which provides power only

when the fan coil blower is operating (See Fig. 2). Infinityt Air

Purifier models GAPABXCC1620,

GAPABXCC2020, and

GAPABXCC2420 are designed to be powered from a 208/230

VAC power source.

A06387

Fig. 2

--- Air Flow Sensor

Door (x1)

Cabinet (x1)

Enhancement Module (x1)

Safety Screen (x1)

Return Duct Adapters:
Long (x2) / Short (x2)

Air Flow Sensor (x1)

(x1)

(x2)

(x3)

(x1)

(x2)

Installation Components

(in bag attached to power cord)

Installation Manual

1

GAPA

Infinity

Air Purifier

Sizes 1620, 2020, & 2420

Installation,

Start---up,

and

Operating

Instructions

NOTE: Re

adthe entire

instructionm

anualbefore

startingthe

install.

TABLE OF

CONTENTS

Page

SAFETY CO

NSIDERATIO

NS

1

. . . . . . . . . . .

. . . . . . . . . . .

. .

INTRODUC

TION

2

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

.

PLANNING

2--5

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . .

Application

2

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . .

InstallationR

equirements

2

. . . . . . . . . . .

. . . . . . . . . . .

. . . .

DimensionsT

able1

3

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . .

Air Conditio

ning

5

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

Humidifiers

5

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . .

OutdoorAir

5

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . .

SheetMetalIn

stallation

5

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . .

Transitions

5

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . .

TurningVane

s

5

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. .

SelectLocatio

n

5

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. .

Directionof A

irflowthroug

hAir Purifier

5

. . . . . . . . . . .

. . .

INSTALLATIO

N

5--6

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

Orientation

5--6

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . .

Details

6

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . .

TypicalMoun

tingPositions

6

. . . . . . . . . . .

. . . . . . . . . . .

. . .

ElectricalInst

allation

6

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . .

FurnaceApp

lication

6

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . .

SYSTEM CH

ECKOUT

7

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . .

MAINTENA

NCE

7

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

.

ReplacingPu

rifierCartrid

ge

7

. . . . . . . . . . .

. . . . . . . . . . .

. .

TROUBLES

HOOTING

7

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . .

Recommen

ded

ServiceTools

7

. . . . . . . . . . .

. . . . . . . . . . .

. .

Indicationof

ElectricalTro

uble

7

. . . . . . . . . . .

. . . . . . . . . . .

OTHERFAC

TS YOU SH

OULDKNO

W

7

. . . . . . . . . . .

. . . .

Ozone

7

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . .

HighAltitud

eOperation

7

. . . . . . . . . . .

. . . . . . . . . . .

. . . . .

Specificatio

ns

Table2

8

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . .

WARRANTY

9

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . .

A05265

Fig. 1 -- Unit

GAPA

SAFETY CO

NSIDERATIO

NS

Improperin

stallation,a

djustment,a

lteration,s

ervice,

maintenanc

e,

or use canca

use explosion

, fire, electric

alshock

or othercond

itionswhichm

aycausepers

onalinjuryorp

roperty

damage.Co

nsult a qualifi

edinstaller, se

rviceagency,

or your

distributoro

r branchfor

informatio

nor assistan

ce.The

qualifiedinst

alleror agenc

ymustusefac

toryauthoriz

edkitsor

accessorie

s

whenmodif

yingthis pro

duct. Refe

r to the

individualin

structionspa

ckagedwith

the kits or a

ccessories

wheninstallin

g.

Followall saf

ety codes. W

ear safety glas

ses and work

gloves.

Use quenc

hingclothfo

r brazingop

erations.H

ave fire

extinguishe

r

available. R

eadthese ins

tructionsthor

oughlyand

follow all w

arningor ca

utionsattach

edto the unit.

Consult

localbuildin

gcodesand N

ationalElect

ricalCode(N

EC) for

specialrequir

ements

.

It is importa

ntto recogn

izesafetyinfo

rmation.Th

is is the

safety--alertsy

mbol

. Whenyou

seethissym

bolontheun

it

andin instru

ctionsor man

uals,be alert

to the pote

ntialfor

personalinju

ry. Underst

andthe sign

al wordsDA

NGER,

WARNING,

andCAUTIO

N. Thesew

ordsareuse

dwith the

safety--alerts

ymbol. DA

NGER iden

tifiesthe mo

stserious

hazardswhic

hwill resulti

n severeper

sonalinjuryo

r death.

WARNING

signifieshaz

ardswhichc

ould resultin

personal

injuryor dea

th. CAUTIO

N is usedto

identifyunsa

fepractices

whichmay

resultin pers

onalinjuryor

productand

property

damage.NO

TE is usedto

highlightsu

ggestionswh

ichwill

resultin enha

nced

installation,re

liability,or op

eration.

Air Purification Cartridge (x1)

(x2)

A07111

Fig. 3

--- Infinityt Air Purifier Components

GAP

A

B

Advertising
This manual is related to the following products: