At the time of air purifier cartridge replacement, if a powdery
residue is noticed on the tips of the points in the ionization
array, proceed to clean them by completing the following
steps:
Step 1

—Turn heating and cooling system power off.

ELECTRICAL SHOCK AND HIGH VOLTAGE

HAZARD
Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than one (1) disconnect

switch.

!

WARNING

Step 2

Turn the Infinityt Air Purifier switch to the off

position.
Step 3

Remove the Infinityt Air Purifier door.

Step 4

Unplug the power cord and flow sensor cable (if

connected) from the enhancement module 9 ( See Fig. 7 and 8)
Step 5

Slide out the enhancement module assembly and safety

screen.

CUT HAZARD
Failure to follow this caution may result in personal

injury.
Sheet metal parts may have sharp edges or burrs. Use

care and wear appropriate protective clothing and

gloves when handling parts.

!

WARNING

Step 6

Slide out the Safety Screen and set aside.

NOTE: Best cleaning tools: 5 inch handle paint brush with 2
inch width (or greater) brush point (synthetic or natural bristle)
(See Fig. 14) or vacuum cleaner with brush attachment.
Step 7

Gently stroke the ionization pins on the top plane of

each bar with enough brush depth to hit front and back tips of the
points in the ionization array. Use a gentle back and forth
brushing motion to clean any small accumulations from the tips
of the points. If desired, use vacuum cleaner with brush
attachment to gently vacuum the frame and components of
enhancement module.
Step 8

Reinstall the Safety Screen.

Step 9

Slide in enhancement module.

Step 10

Reconnect the power cord and flow sensor cable.

Step 11

Replace the Infinityt Air Purifier Door

Step 12

Turn the Infinityt Air Purifier switch to the on

position.
Step 13

Turn heating and cooling system power on .

30°

POINTS ARE SHARP! BE VERY CAREFUL DURING CLEANING.

Tip of point with residue

Tip of point after cleaning

A06671

Fig. 14

--- Removal of Deposits from Ionization Pins

GAP

A

B

Advertising