Caution – Crown Verity SW Series User Manual

Page 13

Advertising
background image

12

SW Series Manual

13

2.0

Installation

Lamp Installation

Figure 2.5

Lamp Installation

NOTE: SW Series heaters are designed for use with Quartz lamp infrared heating elements only. They
are NOT intended to be used with straight metal rod heating elements. Replace lamps with parts
from Crown Verity only.

Figure 2.6

Lamp Installation

1/2” slack on pigtail

Cut off excess

Terminal Screws

Wrap pigtail clockwise
around terminal screw

Lamp Retainers

Lamp Adapter Plates (EL-006)

Lamp Installation

Disconnect power prior to installing or replacing supplied quartz lamp(s). The elements can and should
be installed prior to mounting the heater.

1

Remove the service access panels and open lamp retainers.

2

Position heating elements in “U” slots at the ends of the reflector. When utilizing the ruby lamps, the
lamp adapter plates (EL-006) must first be removed.

3

Close lamp retainers to secure the heating element in the slot (see Figure 2.5).

4

Carefully wrap the heating element pigtail one revolution clockwise around terminal screws (see Figure

2.6).

NOTE: Cut excess pigtail off at terminal to prevent lead from touching metal parts. Avoid

handling the quartz glass as much as possible. Quartz glass should be wiped off with alcohol using a
clean cloth.

5

Tighten the terminal screws (see Figure 2.6).

CAUTION: Do not pull pigtail too tightly that pressure is

being placed on the heating element. Maintain a 1/2” slack in the pigtail.

6

Reinstall service access panels using sheet metal screws as removed in Step 1.

CAUTION

!

Advertising