Maintenance

Troubleshooting Guide

Is there too much heat?

Troubleshooting Guide

Key

Start

Question

Process

Question

Corrective

Action

Turn Heater on from power source.

Does the heating

lamps turn on?

Are the heating lamps

physically damaged?

Are the heating lamps

wired as indicated in

the manual?

Find the source of the electrical problem between panel and heater.

No

No

Yes

Yes

Is there a sufficient

amount of heat?

Is the supply voltage correct for the

model type on the rating label?

Is the heater mounted within the

recommended height?

No

No

Mount heater within the

recommended mounting heights.

Yes

No

No

Yes

Yes

No

Yes

Replace heating lamp(s).

Rewire lamps as indicated

in this manual.

Supply correct voltage

Heater size and/or quantity of

heaters, may be incorrect for

application.

Troubleshooting ends.