background image

AXC-V112

M8x30 DIN 965

Rubber washer

M8x35 DIN 912

Grower (lock) washer

Metal washer

8

EN

Three different washers must be used along

the M8x35 DIN912 screws and placed in the
following

order-

grower

(lock)

washer,

metal

washer and rubber washer.

In order to hang the rest of the boxes the

captive rigging hardware and safety pins will be
used, and the procedures described on the 4.3
paragraph of this manual will be followed. The
picture below shows two

units

hanging from the ceiling.

variant 112A

Before connecting the first box to the ceiling

mount accessory the two M8x30 DIN965 screws
(per side) must be removed from the
and replaced by two M8x35 DIN912.

variant 112A

The

units can be set up as a

cluster of more than three enclosures (as explained
above) or as a small array of 2 units. In the latter
case the highly resistant

grid accessory is

not necessary. Instead the

ceiling mount

accessory can be used to hang a cluster of up to
four units.

First attach the ceiling mount accessory to the

ceiling or a beam. Before doing so be sure that the
load bearing capability of these elements is
enough. The

will be attached to the

ceiling by means of six nº 10 rawlplugs and six 7
x 40 mm screws.