English – CTX Conveyor Oven TCO21140077 User Manual

Page 4

Advertising
background image

ENGLISH

4

Equipotential ground

lug and symbol

(European ovens)

Cable clamp

Terminal

block

Connector

(3-phase ovens only)

Wiring

connections

(3-phase ovens

only)

SECTION 2 - INSTALLATION

IMPORTANT

IT IS THE CUSTOMER’S RESPONSIBILITY TO REPORT ANY

CONCEALED OR NON-CONCEALED DAMAGE TO THE

FREIGHT COMPANY.

A. INSTALLATION OPTIONS & KIT AVAILABILITY

If the installation will require two or three ovens to be stacked,

you must use the separately-available Stacking Kit (P/N

T2114STACK). One Kit is required for a two-stack, while two

kits are required for a three-stack. Stacking more than three

ovens is not permitted.
Wherever the Stacking Kit’s instructions are different from those

listed below, follow the instructions provided with the Kit.

B. ASSEMBLY

1. Installing the Legs

a. Carefully tilt the oven onto its rear side. The front

(controller) side should be facing directly upwards.

b. Thread the four legs into the holes provided on the

bottom of the oven. Tighten them until they are secure.

2. Installing the Conveyor End Trays

a. Press one of the conveyor end trays down over the

end plate of the conveyor frame, as shown in Figure

2.

b. Fasten the end tray in place with one of the supplied

8-32x3/8” screws, as shown in Figure 2.

c. Repeat the above steps to install the second end tray

at the opposite end of the conveyor frame.

CAUTION

THE SUPPLIED LEGS AND THE END TRAYS MUST BE

FASTENED IN PLACE BEFORE OPERATING THE OVEN.

•

The toaster’s power cord and plug provide an electrical

ground connection. A separate equipotential ground con-

nection must also be made if required by national or local

codes.

•

Consult all applicable national and local codes for further

electrical connection requirements.

1. Before proceeding with the electrical connection, check

that the electrical supply matches the oven’s requirements.

Refer to the serial plate and to the Electrical Specifications

table (in Section 1 of this Manual).

WARNING

ENSURE THAT BOTH THE CIRCUIT BREAKER/

FUSED DISCONNECT AND THE POWER ON/OFF (I/

O) SWITCH ARE IN THE “O” (OFF) POSITION BEFORE

PROCEEDING.
WARNING

ENSURE THAT ANY PACKING MATERIAL RESIDUE

HAS BEEN REMOVED FROM INSIDE THE OVEN’S

COOKING CHAMBER.

2. Single-phase Mighty Chef ovens only:

•

Check that the appropriate receptacle is available for

the power cord plug.

•

Insert the power cord plug into its receptacle.

3. Three-phase Mighty Chef ovens only:

•

Remove the two screws that hold the rear cover panel

in place; then, remove the cover panel.

•

Insert the end of the electrical supply through the

connector shown in Figure 3.

•

Attach the electrical supply wires to their terminal block

connections, as shown in Figure 3.

•

Secure the supply wires to the floor of the electrical

compartment using the supplied cable clamp. The

wires must not interfere with the drive chain and

sprocket. See Figure 3.

•

Secure the supply as it passes through the connector

on the outside wall of the oven.

•

Replace the rear wall of the oven and fasten it in place.

4. If required by national or local codes, connect an

equipotential ground wire to the lug shown in Figure 3.

The equipotential ground connection must meet all

applicable national and local code requirements.

C. ELECTRICAL CONNECTION

IMPORTANT
•

Wiring diagrams for the oven are provided on pages 9-10

of this Manual.

•

The electrical connection to the oven requires a circuit

breaker/fused disconnect. Consult applicable national and

local code requirements to determine the rating of the

breaker/disconnect. Electrical specifications are listed on

the oven’s serial plate and in the Electrical Specifications

table (in Section 1 of this Manual).

Figure 2 - End Tray Installation

Position tray

1

Fasten in

place

with screw

2

Repeat for

second tray

3

Figure 3 - Electrical Connections

Advertising