Trouble on operation

Trouble

Check Items

Remedy

Pressing and holding the

MODE1 or MODE2 button

does not turn on a light.

Check whether the Setup

mode is displayed (page 49).

The backlight does not turn on in the Setup

mode.

Check whether

lights up

on the wristwatch screen.

The remaining battery capacity of the wristwatch

is low. Replace it with a new battery (CR2430).

After replacement, be sure to perform the restart-

ing operation (page 14).

Pressing the SSS button

does not start/stop mea-

surement.

Check whether the auto-mode

is turned on (with

illumi-

nating).

When the auto-mode is on ( icon appears),

you cannot start or stop the measurement by

pressing the button. To start/stop measurement

by pressing the SSS button, switch the auto-

mode to off (page 58).

The heart rate sensor

(speed sensor) ID check

failed.

The battery for the heart rate sensor (speed

sensor) is possibly depleted. After replacing the

battery with a new one (CR2032), check the

sensor ID again (page 53).

Lap data cannot be stored. Check whether “--” appears

for the Lap No. screen.

The data volume exceeds the wristwatch mem-

ory capacity. Delete the files (page 45).

When using the optional “USB communication

*

kit”, delete the files after you send the saved

files to your PC.

Does the lap time exceed 100

hours (or the interval distance

exceed 9999.99 km/mile) ?

Laps cannot be measured, if recordable range

described on the left is exceeded. Reset the data

(page 27), and then perform measurement again.

Is it immediately after press-

ing the LAP button?

Recording laps needs at least 5 seconds of in-

terval.

Abnormal values appear.

Are there any objects emitting

electromagnetic waves (railway

tracks, transmitting stations

for television, etc.) nearby?

Keep the unit away from any object that may be

causing interference, and reset the data (page

27).

Any setting cannot be

changed in Option mode or

Setup mode.

Is it during measurement?

Settings can be only viewed during the measure-

ment.

Check whether the auto-mode

is on ( lights up).

When the auto-mode is on ( lights up), the

wristwatch may enter measurement mode due

to electromagnetic waves. Keep the unit away

from any object that may be causing interference

with electromagnetic waves.

Check whether “DATA RESET

is displayed.

To change the target heart rate zone, measure-

ment unit, and record interval, the resetting

operation is required. Stop the measurement,

and perform the resetting operation (page 27).

The record data in the File

view cannot be viewed to

the end.

Check whether

MEMORY FULL” is

displayed on the screen

during measurement.

The data volume exceeds the wristwatch mem-

ory capacity. The data was saved automatically

during measurement, and any subsequent data

was no longer recorded. Delete the files for

subsequent measurement (page 45).

When using the optional “USB communication

*

kit”, delete the files after you send the saved

files to your PC.