Ecler ALMA26 User Manual

Page 14

Advertising
background image

14

8. OUTPUT EDIT MENU

To open the edit menu for the settings of an output, you have to press SHIFT + MUTEx, MUTEx

being the output 1 to 6 MUTE key.

Once in the edit menu for an output, and in one of its pages, it is possible to obtain the same

page for another output by pressing SHIFT + MUTEx, MUTEx being the MUTE key for the other output.

The new edited values are activated in real time. You can cancel an edit operation, bringing back

the value before editing, by pressing SHIFT + CANCEL.

To exit the Edit menu and return to the main screen:
 Press SHIFT + EXIT

 Press SHIFT + MUTEx (the MUTE key of the output x currently edited)
 Stay 2 minutes without operating any control on the front panel


The next page shows the full structure and options of the menu for setting outputs.

NOTES:

1. In the setting pages of the 8 parametric filters available for each output, the displayed

abbreviations meaning is:
 BYP: BYPASS (filter not activated)
 PEQ: PARAMETRIC EQ
 HS6 / HS12: HIGH SHELF 6 or 12 dB/octave
 LS6 / LS12: LOW SHELF 6 or 12 dB/octave
 HP6 / HP12: HIGH PASS 6 or 12 dB/octave
 LP6 / LP12: LOW PASS 6 or 12 dB/octave
 AP1 / AP2: ALL PASS 1st or 2nd order

2. In the setting pages of the Hi-Pass and Low-Pass crossover filters available for each output,

the displayed abbreviations meaning is:
 BYP: BYPASS (filter not activated)
 BES12, 18, 24, 48: BESSEL-type filter, 12, 18, 24 or 48 dB/octave
 BUT6, 12, 18, 24, 48: BUTTERWORTH -type filter, 6, 12, 18, 24 or 48 dB/octave
 LR12, 24, 48: LINKWITZ-RILEY-type filter, 12, 24 or 48 dB/octave

3. The COPY FROM – PASTE TO operation copies all the settings from the source output to the

destination output, except for its source selection (SOURCES) and its name (LABEL)

Advertising