5. BACK PANEL


The back panel features the following connections:

Mains, fuse and power switch (15, 16, 17)

Due to the switched mode power supply, the operating voltage range is 90V – 264V AC, with a

frequency between 47Hz and 63Hz. Before powering up the unit, make sure that the ALMA26 is
correctly connected to ground in a facility that complies with local regulations.

Input (12) and output (13) connectors

The ALMA26 has two balanced audio inputs (CH1 and CH2) on 3-pin female XLR connectors

(pin 1 to ground, pin 2 to signal + (positive) and pin 3 to signal – (negative)). The ALMA26's signal output
is performed through six balanced outputs (OUTPUT1-6), on 3-pin male XLR connectors. As for inputs,
the connectors are configured with the pin 1 to ground, pin 2 to signal + (positive) and pin 3 to signal –
(negative).

REMOTE connectors (14)

The A and B REMOTE connectors allow you to simultaneously control the volume of one or

multiple inputs, or one or multiple outputs through a WPm series wall panel or similar (0-10VDC). The
inputs or outputs controlled through each REMOTE port are selected using the device setup menu (front
keys and LCD display) or from EclerCOMM Manager software.