Critical operation conditions of the MAC 10

1. Touching of the HEPA filter could damage it, voiding the warranty on the

filter. The screen is only to protect against an accidental ‘touch’ of the
filter. Never place a hand or tool on the filter. Never lie filter face flat
down on a surface always have filter on its side or back to protect from
damage.

2. Prior to powering the unit, verify that the unit has been plugged into the

correct voltage. The serial number label on the top of the Mac 10 unit
has the required voltage.

3. For reorder prepossess the Mac 10 part number and serial number

should be recorded. This information is located on the serial number
label, located adjacent to the electrical box. If you can’t located the Sales
Order Number please contact Envirco for this information.

Part Numbers Covered by this Manual

11111-XXX

Mac 10 Original 2x4 Standard Filter

11112-XXX

Mac 10 Original 2x3 ½ Standard Filter

11113-XXX

Mac 10 Original 2x3 Standard Filter

11114-XXX

Mac 10 Original 2x2 Standard Filter

11115-XXX

Mac 10 Original 2x4 RSR Filter Sheet Metal Housing

11116-XXX

Mac 10 Original 2x3 ½ RSR Filter Sheet Metal Housing

11117-XXX

Mac 10 Original 2x3 RSR Filter Sheet Metal Housing

11118-XXX

Mac 10 Original 2x2 RSR Filter Sheet Metal Housing

11157-XXX

Mac 10 Original 2x4 RSR Filter Extrusion Housing

11171-XXX

Mac 10 Original 2x3 ½ RSR Filter Extrusion Housing

11169-XXX

Mac 10 Original 2x3 RSR Filter Extrusion Housing

11170-XXX

Mac 10 Original 2x2 RSR Filter Extrusion Housing


Note: A ‘Z’ in the part number indicates that the unit is special. This may
indicate a size change from standard or a special filter. Please contact
the factory for part numbers if this is the situation.