Protect the extension cords from sharp

8.

objects, excessive heat, and damp or

wet areas.

recOMMended MiniMuM wire

gauge FOr extenSiOn cOrdS*

(120/240 VOlt)

naMeplate

aMpereS

(at full load)

extenSiOn cOrd

length

25’

50’

75’

100’

150’

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

taBle a

* Based on limiting the line

voltage drop to five volts at

150% of the rated amperes.