15

B

EFORE

U

SE

GYRO SENCE

01 . MODEL-01. NORML HEL PCM 0: 23: 17

DUAL

: MODE

: GAIN 1

: GAIN 2

0

20

40

60

80 100 END

85 %

15 %

85%

15%

GAIN1

setting

GAIN2

setting

70%

30%

AVCS side

Normal side

70%

40%

(Setting Example)

Adjust the gyro gain at the Gyro Sense Mixing setup screen at each
condition.
The following shows a setting example in the CMT mode.

Select the Dual Mode (DUO).

Sensitivity rate
Choose the GAIN1 or GAIN2 by the CH5 switch.

Use the following values as the sensitivity setting standard:

CH5 switch

Actual gain

Hovering

Flight

The GY501 sensitivity is 0% at 50%. When set over 50%, the GY501
operates in the AVCS mode and when set under 50%, the GY501
operates in the Normal mode. When setting is changed 1%, the gyro
sensitivity is changed 2%.