This appendix provides cable requirements for each of the EMC38-12
ports.

A.1

10Base-T TWISTED PAIR REQUIREMENTS

When you connect a 10Base-T twisted pair segment to the EMC38-12,
the device at the other end of the twisted pair segment must meet IEEE
802.3 10Base-T specifications. Your 10Base-T twisted pair segment must
meet the following requirements.

Segment Length

The IEEE 802.3 10Base-T standard requires that 10Base-T devices must
be able to transmit from 0 to at least 100 meters (328 feet) per segment of
24-gauge unshielded twisted pair (UTP) cable.

Insertion Loss

The maximum insertion loss allowed for a 10Base-T segment is 11.5 db
at all frequencies between 5.0 and 10.0 MHz. This includes the
attenuation of the cable, connectors, and patch panel.

Impedance

10Base-T specifies cable impedance between 85 and 110 ohms.