Coil Charge Time (ms)

This field is only applicable when constant charge is selected. The value of this field
is a measure of time in milliseconds and can range from 0.1ms - 8.2ms. Typical values
are about 4-5ms.

Output Edge

This field defines which edge of the signal triggers the ignition event: falling or rising.
The EB023 smart igniter uses a falling edge.


Constant Duty Cycle

This field defines the duty cycle high time when using the constant duty output type
with a smart igniter. For the EB023 smart igniter the duty cycle high time is 70% with
a corresponding 30% low time.

NOTE:

Now that the ignition set-up is correct the ignition system may be connected to

the ECU. Be sure that the ECU is reset (by turning the key “off” then “on”)

before you connect the ignition system to be sure that the ECU has enabled any

changes made to the set-up.

4.2.4 Trigger Setup


Trigger Angle -

°°°°BTDC

This field defines the angle in

°BTDC at which the ECU will be triggered. The ECU

uses this value to calculate the time for the next ignition so it is important that this
value is correct since it will affect the base ignition timing. This setting also appears in
the Ignition Set-up page for convenience.

Trigger Type

This field defines the trigger pattern the ECU will see coming from the crank or
camshaft angle sensors. The E6X currently supports the following trigger types:

Standard
Multi-tooth

Motronic

Subaru A (Up to MY00)

Twin Trigger

Daihatsu (extra tooth)

Nissan

Mazda

(FS)

Subaru A (From MY00)

MGF