Buttons

: Click to save changes.

: Click to undo any changes made locally and revert to previously saved values.


By default, the system automatically detects the speed and duplex mode used on each port, and configures the path cost
according to the values shown below. Path cost “0” is used to indicate auto-configuration mode. When the short path cost
method is selected and the default path cost recommended by the IEEE 802.1w standard exceeds 65,535, the default is set to
65,535.

Port Type

IEEE 802.1D-1998

IEEE 802.1w-2001

Ethernet

50-600

200,000-20,000,000

Fast Ethernet

10-60

20,000-2,000,000

Gigabit Ethernet

3-10

2,000-200,000

Table 4-7-1:

Recommended STP Path Cost Range

Port Type

Link Type

IEEE 802.1D-1998

IEEE 802.1w-2001

Ethernet

Half Duplex
Full Duplex
Trunk

100
95
90

2,000,000
1,999,999
1,000,000

Fast Ethernet

Half Duplex
Full Duplex
Trunk

19
18
15

200,000
100,000
50,000

Gigabit Ethernet

Full Duplex
Trunk

4
3

10,000
5,000

Table 4-7-2:

Recommended STP Path Costs

Port Type

Link Type

IEEE 802.1w-2001

Ethernet

Half Duplex
Full Duplex
Trunk

2,000,000
1,000,000
500,000

Fast Ethernet

Half Duplex
Full Duplex
Trunk

200,000
100,000
50,000

Gigabit Ethernet

Full Duplex
Trunk

10,000
5,000

Table 4-7-3:

Default STP Path Costs