Connections, Connections 6 – Interlogix TruVision IP Open Standards Box User Manual User Manual

Page 10

Advertising
background image

1BChapter 2: Installation

Connections

A qualified service person, complying with all applicable codes, should perform
all required hardware installation.

Note

: Do not attempt to extend the power/data cable connection using RJ45

couplers and Cat5 cable. Only use the data cable connection provided.

Note

: Use 12 VDC or PoE.

Figure 3: Wiring the camera

1. Ethernet RJ45 PoE port

Connect to network devices.

2. Video

output

Connect to a CCTV monitor.

3. Audio

output

Connect to an audio output.
Line level, 600 Ω.

4. Audio

input

Connect to an audio input.
2.0 to 2.4 Vp-p, 1 kΩ.

5. Power

LED

Illuminated when power is connected.

6. Power

supply

Connect +12 VDC power supply.

7. RS-485 D+, D-

Connect to an RS-485 device such as a
PTZ dome camera.

8. Alarm outputs

Connect 1A/1B and 2A/2B to alarm output
devices.

9. Alarm

inputs

Connect IN1/GND and IN2/GND to alarm
input devices.

10. Ground

Connect to ground.

Note:

The alarm output can be used to turn on and off an external alarm device.

Connect a 12 VDC/30 mA external power supply to the alarm output. See
Figure 4 below.

6

TruVision IP Cam Open-Standards User Manual