Rs-485 settings 32, Rs-485 settings – Interlogix TVE Series User Manual

Page 36

Advertising
background image

32

TVE-400/800-1600 H.264 IP Video Encoder User Manual

4. Click the

Start Draw

buton to start drawing an area.

5. Using the mouse, click and drag a privacy-mask box in the camera view

screen over the desired area. You can set up to four areas for privacy
masking.

6. Click the

Stop Draw

button to stop drawing.

Note: Click the

Clear All

button to clear all mask areas.

7. Click

Save

to save the settings.

RS-485 settings

The RS-485 serial port is used to control the PTZ of the camera. The PTZ
parameters need to be configured before you control the PTZ unit.

To configure a privacy mask:

1. Click

Device Configuration

>

Serial Port Settings

>

RS-485.

The RS-485

window appears.

2. Enter the RS-485 parameters. The default parameters are:

Baud rate: 9600

Data bit: 8

Stop bit: 1

Parity: None

Flow control: None

PTZ protocol: A-01

Address: 0

Note:

It is important to ensure that the settings correspond with those used in

the PTZ camera.

Advertising