GENERAL

Installation of the unit must be accomplished by quali-
fied electrical installation personnel working to all appli-
cable local and national codes. Improper installation of
product could cause injury or damage.

This equipment is built to comply with applicable stan-
dards for manufacturers. Included among those
approval agencies are: UL, NSF, ASME/Ntl. Bd., CSA,
CGA, ETL, and others. Many local codes exist, and it is
the responsibility of the owner/installer to comply with
these codes.

Note: Maximum voltage for LVD (low volt directive for
Europe) to be 440 volts for CE marked appliances.

INSPECTION / UNPACKING

Note: The electrical rating label is located on the right
console. Serial number, voltage, phase, amperage and
wattage are stated on this label.

1. Before unpacking visually inspect the unit for evi-

dence of damage during shipping.

2. If damage is noticed, do not unpack the unit, follow

"SHIPPING DAMAGE INSTRUCTIONS" shown below.

3. Carefully remove unit from shipping carton. Remove

any packing material from unit. After carefully
unpacking check for "concealed" damage. If dam-
age is noticed, follow "SHIPPING DAMAGE
INSTRUCTIONS" shown below.

4. Check the electrical rating label to ensure that the

unit is the correct voltage, phase, amperage and
wattage are stated on this label.

5. A protective material has been applied to the stain-

less steel panels. This material must be removed
immediately after installation, as heat will melt the
material and make it more difficult to remove.

SHIPPING DAMAGE
INSTRUCTIONS

If shipping damage to the unit is discovered or suspect-
ed, observe the following guidelines in preparing a ship-
ping damage claim.

1. Write down a description of the damage or the rea-

son for suspecting damage as soon as it is discov-
ered. This will help in filling out the claim forms later.

2. As soon as damage is discovered or suspected, noti-

fy the carrier that delivered the shipment.

3. Arrange for the carrier's representative to examine

the damage.

4. Fill out all carrier claims forms and have the examin-

ing carrier sign and date each form.

CLEARANCE REQUIREMENTS

This unit must be installed in accordance with the clear-
ances shown on the rating label which is adhered to the
unit.

FOR YOUR SAFETY. Keep the appliance area free and
clear of combustible materials.

INSTALLATION

Note: For clearance requirements, suggested drain
location and assembly details refer to Specification
Sheet.

1. Position the unit in it's permanent location, and level

the unit by turning the adjustable feet.

2. Once positioned

and leveled, per-
manently secure
the unit's rear
flanged feet to the
floor using 5/16"
lag bolts and floor
anchors (supplied
by the installer).
Three bolts are
required to secure each of the flanged feet.

3. Seal joints of flanged feet with a silicone sealant.

INSTALLATION

7/16"Ø, 3 HOLES
ON 3 1/8" (80mm) B.C.D.

FLANGED FOOT DETAIL

(REAR LEGS ONLY

)

120

120

4 7/8" (124mm)