G-Series Touchpanel Interface

Crestron TPS-GA-TPI

To open the QM AUDIO OUTPUT SETUP menu, press the QM Output button on
the GENERAL AUDIO SETUP menu. The QM AUDIO OUTPUT SETUP menu
offers a series of buttons that adjust the Program Gain and Transmit QM ID.

The Restore Default Output Settings button returns all audio parameters on this
menu to their default settings. Program Gain buttons and Transmit QM ID Manual
and Auto buttons are provided to adjust QM audio output. After these parameters
have been set, select the Return button to return to the SETUP MENU.

QM AUDIO OUTPUT SETUP MENU

Refer to the following table for additional QM AUDIO OUTPUT SETUP menu
details.

QM Audio Output Setup Details

QM AUDIO

OUTPUT SETUP

SCREEN

CONTROLS

DESCRIPTION

Restore Default
Output Settings

Returns the settings on this menu to their factory
defaults.

Program Gain

This controls the volume of the QM Program audio sent
to the QM output with the and + buttons.

Transmit QM ID

Allows transmission of touchpanel’s QM ID for use in QM
systems utilizing auto compensation*. Manual will
transmit a specific QM ID, adjustable with the Down and
Up

Buttons. Auto, the default setting, will transmit the

Cresnet ID as the QM ID.

* Auto compensation automatically recalls program gain settings when acting as an origination point.