Install the door control, Installation step 6, Figure 1 figure 2 – Craftsman 139.53915D User Manual

Page 17

Advertising
background image

17

To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door

control.

• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
• Install door control within sight of garage door, out of reach

of children at a minimum height of 5 feet (1.5 m) and away
from ALL moving parts of door.

• NEVER permit children to operate or play with door control

push buttons or remote controls.

• Activate door ONLY when it can be seen clearly, is properly

adjusted and there are no obstructions to door travel.

• ALWAYS keep garage door in sight until completely closed.

NEVER permit anyone to cross path of closing garage door.

INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of door, at a minimum height of
5 feet (1.5 m) where small children cannot reach, away from
moving parts of door and door hardware. If installing into drywall,
drill 5/32" holes and use the anchors provided. For pre-wired
installations (as in new home construction), it may be mounted to
a single gang box (Figure 2).

1. Strip 7/16" (11 mm) of insulation from one end of bell wire and

connect to the two screw terminals on back of door control by
color: white wire to 2 and white/red wire to the 1.

2. Remove cover by gently prying at slot in top of the cover with

a small flat head screwdriver. Fasten with 6ABx1-1/4"
self-tapping screws (drywall installation) or 6-32x1" machine
screws (into gang box) as follows:

• Install bottom screw, allowing 1/8" (3 mm) to protrude above

wall surface.

• Position bottom of door control on screw head and slide

down to secure. Adjust screw for snug fit.

• Drill and install top screw with care to avoid cracking plastic

housing. DO NOT overtighten.

• Insert top tabs and snap on cover.

3. (For standard installation only) Run bell wire up wall and

across ceiling to motor unit. Use insulated staples to secure
wire in several places. DO NOT pierce wire with a staple,
creating a short or open circuit.

4. Strip 7/16" (11 mm) of insulation from end of bell wire.

Connect bell wire to the quick-connect terminals as follows:
white to white and white/red to red.

NOTE:

When connecting multiple door controls to the opener,

twist same color wires together. Insert wires into
quick-connect holes: white to white and red/white to red.

5. Position the antenna wire as shown.

6. Use tacks or staples to permanently attach entrapment warning

label to wall near door control, and manual release/safety
reverse test label in a prominent location on inside of garage
door.

NOTE: DO NOT connect power and operate opener at this time.
The trolley will travel to the full open position but will not return
to the close position until the sensor beam is connected and
properly aligned.

Outside Keylock Accessory Connections

To opener quick-connect terminals: white to white; white/red to
red.

LOCK

LIGHT

To Replace,
Insert Top
Tabs First

PRE-WIRED
INSTALLATION

REMOVE & REPLACE COVER

Figure 1

Figure 2

24 Volt
2-Conductor
Bell Wire in
Gang Box

LOCK

LIGHT

Lock

Light

2-Conductor
Bell Wire

Terminal
Screws

(BACK VIEW)

Top
Mounting
Hole

Bottom
Mounting
Hole

WHITE

2

RED

1

Bell
Wire

K

1

3

9

7

5

KG

1

3

9

7

5

Quick-Connect
Terminals

7/16" (11 mm)

Door Control
Connections

To release or insert wire,
push in tab with
screwdriver tip

Antenna

Red

Grey

White

Push Bar

LOCK

LIGHT

Strip wire 7/16"
(11 mm)

Drywall Anchors

Insulated
Staples

Screw 6ABx1-1/4"
(std installation)

Screw 6-32x1"
(pre-wired)

HARDWARE SHOWN ACTUAL SIZE