Having a problem – Craftsman 139.53915D User Manual

Page 33

Advertising
background image

33

HAVING A PROBLEM?

1. My door will not close and the light bulbs blink on my motor

unit: The safety reversing sensor must be connected and
aligned correctly before the garage door opener will move in
the down direction.

• Verify the safety sensors are properly installed, aligned and

free of any obstructions. Refer to Installation Step 10: Install
The Protector System

®

.

• Check diagnostic LED for flashes on the motor unit then refer

to the Diagnostic Chart on the following page.

2. My remotes will not activate the door:

• Verify your Motion Detecting Control Console is not blinking.

If it is blinking, deactivate the Lock Mode following the
instructions for Using the Motion Detecting Control Console.

• Reprogram remotes following the programming instructions.

Refer to Programming.

• If remote will still not activate your door, check diagnostic

LED for flashes on motor unit then refer to Diagnostic Chart
on the following page.

3. My door reverses for no apparent reason: Repeat safety

reverse test after adjustments to force or travel limits. The need
for occasional adjustment for the force and limit settings is
normal. Weather conditions in particular can affect door travel.

• Manually check door for balance or any binding problems.

Refer

to

Adjustment Step 2, Adjust the Force.

4. My door reverses for no apparent reason after fully closing

and touching the floor: Repeat safety reverse test after
adjustments to force or travel limits. The need for occasional
adjustment for the force and limit settings is normal. Weather
conditions in particular can affect door travel.

Refer

to

Adjustment Step 1, Adjust the UP and DOWN Travel

Limits. Decrease down travel by turning down limit
adjustment screw clockwise.

5. My lights will not turn off when door is open:

• The garage door opener is equipped with a security light

feature. This feature activates the light on when the safety
sensor beam has been obstructed. Refer to Operation
section; Using the Wall Mounted Door Control, Light Feature.

Safety Reversing Sensor

Bell Wire

“Learn”
Button
LED or
Diagnostic
LED

Receiving Eye Safety Reversing
Sensor (Green Indicator Light)

Sending Eye Safety Reversing
Sensor (Amber Indicator Light)

6. My motor unit hums briefly:

• First verify that the trolley is against the stop bolt.

• Release the door from the opener by pulling the Emergency

Release Rope.

• Manually bring the door to a closed position.

• Loosen the belt by adjusting the outer nut 4 to 5 turns. This

relieves the tension.

• Run the motor unit from the remote control or door control.

The trolley should travel towards the door and stop. If the
trolley re-engages with the door, pull the Emergency Release
Rope to disengage.

• Decrease the UP travel by turning the UP Travel adjustment

screw 2 full turns away from the arrow.

• Re-Tighten the outer nut until the trolley spring is

approximately 1-1/4" (3.18 cm) in length.

• If the trolley does not move away from the bolt, repeat the

steps above.

Trolley

1-1/4"

(3.18 cm)

Advertising