MINIMUM BURNER SETTING ADJUSTMENT

Figure 27

A

The operations must be executed by a qualified technician.

IMPORTANT
All intervention regarding installation maintenance and conversion of the
appliance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of
this obligation.

Lubrication of the gas taps

Check whether the flame spreads to all
burner ports when the burner is lit with
the gas tap set to the minimum
position. If some ports do not light,
increase the minimum gas rate setting.

Check whether the burner remains lit
even when the gas tap is turned
quickly from the maximum to the
minimum position. If the burner does
not remain lit, increase the minimum
gas rate setting.

The adjustment is performed with the
burner lit, as follows:

Turn the knob to the minimum
position.

Remove the knob.

Using a screwdriver turn screw "A"
until the flame setting is correct.

Normally for LPG, fully tighten the
adjustment screw.