Troubleshooting – Craftsman 919.15216 User Manual

Page 17

Advertising
background image

17 - ENG

TROUBLESHOOTING

Risk of Unsafe Operation. Unit cycles automatically when

power is on. When servicing, you may be exposed to

voltage sources, compressed air, or moving parts. Before servicing unit

unplug or disconnect electrical supply to the air compressor, bleed tank of

pressure, and allow the air compressor to cool.

PrOBLeM

CAUSE

COrreCTiON

Excessive tank pressure

- safety valve pops off.

Pressure switch does

not shut off

motor when

compressor reaches

"cut-out" pressure.

Move On/Off lever to

the "Off" position,

if

the outfit does not shut

off contact a Trained

Service Technician.

Pressure switch "cut-

out" too high.

Contact a Trained

Service Technician.

Air leaks at fittings.

Tube fittings are not tight

enough.

Tighten fittings where air

can be heard escaping.

Check fittings with

soapy water solution.

Do

Not Overtighten.

Air leaks in air tank or at

air tank welds.

Defective air tank.

Air tank must be

replaced. Do not repair

the leak.

Risk bursting. Do

not drill into, weld or

otherwise modify air

tank or it will weaken.

The tank can rupture

or explode.

Air leaks between head

and valve plate.

Leaking seal.

Contact a Trained

Service Technician.

Air leak from safety

valve.

Possible defect in safety

valve.

Operate safety valve

manually by pulling on

ring. If valve still leaks, it

should be replaced.

Knocking Noise.

Possible defect in safety

valve.

Operate safety valve

manually by pulling on

ring. If valve still leaks, it

should be replaced.

Advertising