Interface connectors, Front of adit, Back of adit – Carrier Access Adit 3200 User Manual

Page 12: Grounding the unit

Advertising
background image

12

Adit 3200 - Release 1.6

Quick Start

Interface Connectors

Interface Connectors

The following are the Adit 3200 interface connectors:

Front of Adit

z

(1) DS1 WAN port (RJ-48C). Note: E1 will be in a future release.

z

(1) 10/100Base-T WAN port (RJ-45)

z

(4) 10/100Base-T switched LAN ports (RJ-45)

Back of Adit

z

RS-232 craft port connector for local management

z

Power input connector

z

Ground connector

Grounding the Unit

WARNING!

T

HE

A

DIT

3200

IS

REQUIRED

TO

BE

PERMANENTLY

GROUNDED

FOR

THE

PROTECTION

OF

USERS

AND

SERVICE

PERSONNEL

.

Chassis ground is located on the back of the unit.
To ground the unit:

1. Connect a minimum 14 AWG ground

wire with a #8 ring tongue terminal (not
included) to the chassis ground on the
back of the unit. Secure with the 8-32
screw and lock washer provided.

2. Connect the opposite end of the ground

wire to a suitable earth grounding point
such as a building grounding electrode,
metal water pipe, or metal building
structure that is in compliance with article 250 of NEC.

Chassis
Ground

Advertising