Alarm/status leds – Carrier Access Adit 3200 User Manual

Page 17

Advertising
background image

Adit 3200 - Release 1.6

17

Quick Start

Alarm/Status LEDs

Alarm/Status LEDs

LED

State

Description

Critical

Off

No critical alarms present

Red

Critical alarms present. Critical alarms include:
user-configured manor environmental inputs.

Major

Off

No major alarms present

Red

Major alarm present. Major alarms include:
user-configured manor environmental inputs, DS1 short, DS1 open, DS1
facility alarm, DS1 RAI, DS1 AIS, DS1 LOF, DS1 LOS, WAN fault,
Ethernet fault and dead card alarms.

Minor

Off

No minor alarms present

Red

Minor alarms present. Minor alarms include:
user-configured minor environmental inputs, DS1 excessive line code
violations.

Status

Off

No power to system

Green

Application running, no detected system problems.

Green Flashing

Power-On Self Test (POST) successful. System booted. Loading
Application.

Green/Yellow

Flashing alternate colors. Application Self Test in Process.

Yellow

Yellow while booting. If this stays a steady yellow the Power-On Self Test
(POST) failed.

Yellow Flashing

Power-On Self Test (POST) In Process.

Red

System Failure