Power, Battery connection – Carrier Access Adit 3200 User Manual

Page 13

Advertising
background image

Adit 3200 - Release 1.6

13

Quick Start

Interface Connectors

Power

The Adit 3000 is powered by a limited -48 VDC Power source. The
following options are available:

z

AC/DC Converter

z

Battery Backup module

AC/DC Converter

An AC/DC Converter generates 48VDC from any worldwide AC power source.
To connect AC power:
1. Plug power connector from AC/DC converter into rear of Adit 3000.
2. Connect AC/DC converter to wall outlet.
3. A green light should appear on the Status LED on the front of the unit.

CAUTION!

I

NCORRECT

WIRING

OF

CORD

MAY

CAUSE

EXTERNAL

FUSE

FAILURE

.

WARNING!

P

OSSIBLE

SHOCK

HAZARD

EXISTS

,

PLEASE

FOLLOW

INSTRUCTIONS

CAREFULLY

.

To connect -48 VDC power:
1. Wire appropriate connector to open end of the DC Power cable.

Orange = -48 Black = Ground (+)

2. Plug the DC power connector in the -48 VDC input power connector.
3. Apply power to connector from -48 VDC power source.
4. A green light should appear on the Status LED on the front of the unit.

WARNING!

E

XTERNAL

FUSE

PROTECTION

IS

REQUIRED

ON

THE

48VDC

INPUT

WHEN

CONNECTED

TO

A

DC

POWER

SOURCE

NOT

SUPPLIED

BY

C

ARRIER

A

CCESS

.

Fuse Recommendations, or equivalent:

Battery Connection

The Adit 3000 Battery connection is provided for Battery Backup. See Adit 3104, 3200, 3300 and 3400
Battery Backup
on page 8
for additional information.

Recommended Fuse

AMP Rating

Littelfuse 48101.5

1.5 Amp

Bussman GMC-1.5A

1.5 Amp

PIN 10, ORANGE
PIN 5, BLACK