Seneca clearance chart, Dutchwest seneca – Vermont Casting 2170 User Manual

Page 12

Advertising
background image

12

Dutchwest Seneca

2006063

Seneca Clearance Chart

Stove Clearance

Stove Installed
Parallel to Wall

Unprotected Surfaces

Protected Surfaces

Side

Rear

Corners

Side Rear

Corners

No stove

heat shields

Chimney Connector Clearance

Unprotected Vertical Surfaces

Protected Vertical Surfaces

Clearance to Combustibles in Front of Stove

48” (1220 mm)

24” (610mm)

16” (410mm)

16” (410mm)

16” (410mm)

All Installations

Stove Installed
Parallel to Wall

Stove

in

Corner

Stove

in

Corner

Stove, top exit with rear

heat shield, no connector

heat shields

1

(A) 18”

(B) 28”

(C) 21”

(D) 8”

(E) 20”

(F) 13”

(460mm)

(710mm)

(530mm)

(200mm)

(510mm)

(330mm)

(M) 18”

(N) 20”

(O) 13”

(P) 8”

(Q) 20”**

(R) 13”

(460mm)

(510mm)

(330mm)

(200mm)

(510mm)

(330mm)

(G) 18”

(H) 28”

(I) 21”

(J) 8”

(K) 20”

(L) 13”

(460mm)

(710mm)

(530mm)

(200mm)

(510mm)

(330mm)

Stove, top exit with rear

heat shield, and heat

shields on connector

1,2

Stove, rear exit with rear

heat shield only

(S) 18”

(T) 16”

N/A

(U) 8”

(V) 10”

N/A

(460mm)

(410mm)

(200mm)

(255mm)

No chimney connector
heat shields

Chimney connector
heat shields installed

2

1

Shielding for a top exit stove must include a shield insert to protect the area behind the flue collar.

2

Chimney connector heat shields must extend exactly 28” (710mm) above the flue collar of the stove.

** The rear clearance may be reduced to a minimum of 15” (381mm) and chimney connector clearance reduced to a
minimum of 12” (305mm) if:

a. The wall shield is at least 77” high and 48” wide, and the shield is constructed as shown on Page 10.
b. The chimney connector heat shield extends exactly 23” (584mm) above the flue collar of the stove.
c. A 24” (610mm) in diameter ceiling heat shield is installed.